Section 2
Clearance Requirements
AIR/WATER/REMOTE MODELS
IT0300
Contained
Air-Cooled
Top/Sides
16" (40 cm)
Back
5" (13 cm)
IP0320 IT0420
Contained
IT0620
Air-Cooled
Top/Sides
12" (31 cm)
Back
5" (13 cm)
IT0450 IT0500
IF0500 IP0500
Contained
IF0600 IT0750
Air-Cooled
IF0900 IT0900
Top/Sides
8" (20 cm)
Back
5" (13 cm)
NOTE: Top air discharge kits require the
same clearance requirements as the
comparable self-contained air-cooled
model.
IT1200 60 Hz
Contained
Air-Cooled
Top/Sides
8" (20 cm)
Back
5" (13 cm)
IT1200 50 Hz
Contained
Air-Cooled
Top
12" (31 cm)
Sides
23" (58 cm)
Back
8" (20 cm)
Part Number 000014141 Rev 11 12/23
Self-
Water-Cooled
8" (20 cm)
5" (13 cm)
Self-
Water-Cooled
or Remote
Condenser
8" (20 cm)
5" (13 cm)
Self-
Water-Cooled
or Remote
Condenser
8" (20 cm)
5" (13 cm)
Self-
Water-Cooled
or Remote
Condenser
8" (20 cm)
5" (13 cm)
Self-
Water-Cooled
or Remote
Condenser
8" (20 cm)
8" (20 cm)
5" (13 cm)
Self-Contained
IT1500
Air-Cooled
Top
12" (31 cm)
Sides
8" (20 cm)
Back
12" (31 cm)
Self-Contained
IT1900
Air-Cooled
Top/Sides
24" (61 cm)
Back
12" (31 cm)
Bristol Compressor
Self-Contained
1IT1900
Air-Cooled
Top/Sides
8" (20 cm)
Back
5" (13 cm)
1Copeland Compressor
REMOTE CONDENSOR MODELS
Model
Top
JCF0500
JCT0500
JCF0900
36"
JCT0900
(91 cm)
JCT1200
JCT1500
* Minimum of two sides.

Notice
Condensers must be mounted horizontally
with the fan motor on top with nothing
obstructing it.
Installation
Water-Cooled
or Remote
Condenser
8" (20 cm)
8" (20 cm)
5" (13 cm)
Water-Cooled
or Remote
Condenser
8" (20 cm)
5" (13 cm)
Water-Cooled
or Remote
Condenser
8" (20 cm)
5" (13 cm)
Sides*
Bottom
24"
16"
(61 cm)
(41 cm)
15