ELECTRICAL SERVICE

All wiring must conform to local and national codes.
Voltage
The maximum allowable voltage variation is ± 10% of
the rated voltage on the ice machine model/serial
number plate at compressor start-up.
Fuse/Circuit Breaker
A separate fuse/circuit breaker must be provided for
each ice machine.
The ice machine must be grounded in accordance
with national and local electrical codes.
Ground Fault Interrupter Circuit (GFIC)
A GFCI/GFI circuit protection is not recommended
with our equipment. If a GFCI/GFI is required by code
a GFCI/GFI breaker rather than outlet must be used to
avoid intermittent nuisance trips.