Section 3

Minimum/Maximum Slab Weight

Adjust ice thickness to meet chart
specifications.
Model
IT0300 IP0320
1089 grams
IT0420 IT0450
IT0620C
1542 grams
IT0500 IF0500
IP0500
2087 grams
IF0600 IT0750
1869 grams
IBF0820C
2608 grams
IF0900 IT0900
2812 grams
IT1200
IBT1020C
3402 grams
IF1400C
IT1430C
5443 grams
IT1500
4649 grams
IF1800C
IT1830C
7031 grams
IT1900
5987 grams
IF2100C
IT2130C
7257 grams

Notice
Routine adjustments and maintenance
procedures are not covered by the
warranty.
Part Number 000014141 Rev 11 12/23
Minimum
Maximum
Ice Weight
Ice Weight
Per Cycle
Per Cycle
lbs
lbs
Grams
Grams
2.40 lbs
2.80 lbs
1270 grams
3.40 lbs
3.90 lbs
1769 grams
4.60 lbs
5.20 lbs
2359 grams
4.12 lbs
4.75 lbs
2155 grams
5.75 lbs
6.50 lbs
2948 grams
6.20 lbs
7.20 lbs
3266 grams
7.50 lbs
8.20 lbs
3719 grams
12.00 lbs
14.00 lbs
6350 grams
13.20 lbs
14.80 lbs
5216 grams
15.5 lbs
16.75 lbs
7598 grams
13.20 lbs
14.80 lbs
6713 grams
16.00 lbs
17.25 lbs
7824 grams

Ice Thickness Check

After a harvest cycle, inspect the ice cubes
in the ice storage bin. The ice thickness
probe is factory-set to maintain the ice
bridge thickness at 1/8" (3 mm).
NOTE: Make sure the water curtain is
in place when performing this check. It
prevents water from splashing out of the
water trough.
1.
Inspect the bridge connecting the
cubes. It must be approximately
1/8" (3 mm) thick.
2.
If adjustment is necessary, turn the
ice thickness probe adjustment screw
clockwise to increase bridge thickness,
counterclockwise to decrease bridge
thickness. Set a 9/32" (7 mm) gap
between ice thickness probe and
evaporator as starting point, then
adjust to achieve a 1/8" (3 mm) bridge
thickness.
NOTE: Turning the adjustment one-third of
a turn will change the ice thickness about
1/16" (1.5 mm).
ADJUSTING SCREW
1/8" (3 mm)
ICE BRIDGE THICKNESS
PLACE 9/32"
(7 mm) DRILL BIT
BETWEEN PROBE AND
EVAPORATOR TO SET
INITIAL GAP
Verify the ice thickness probe wire doesn't
restrict probe movement.
Operation