Installation
Design & Burst Pressure
Design Pressure 600 psig - 4137 kPa
Burst Pressure 2500 psig - 17237 kPa
Head Pressure Control Valve
Do not use a fan cycling control to try to
maintain discharge pressure. Compressor
failure will result. Any remote condenser
connected to a Manitowoc Ice Machine
must have the OEM head pressure control
valve installed. Manitowoc will not accept
substitute "off the shelf" head pressure
control valves.
Kits are available for head pressure control
installation:
• R404A Refrigerant - K00479
• R410A Refrigerant - K00221
Fan Motor
The condenser fan must be on during the
complete ice machine freeze cycle (do
not cycle on fan cycle control). The ice
maker has a condenser fan motor circuit
for use with a Manitowoc condenser. It is
recommended that this circuit be used to
control the condenser fan(s) on the multi-
circuit condenser to assure it is on at the
proper time. Do not exceed the rated amps
for the fan motor circuit listed on the ice
machine's serial tag.
36
Internal Condenser Volume
The multi-circuit condenser internal
volume must not be less than or exceed
that used by Manitowoc. Do not exceed
internal volume and try to add charge to
compensate, as compressor failure will
result.
Model
IT0500N
IF0500N
IF0600N/IF0900N
IT0750N/IT0900N/
IT1200N
IT1500N/IT1900N
Heat of Rejection
Model
IF0500N
IT0500N
IF0600N
IT0750N
IF0900N
IT0900N
IT1200N
IT1500N
IT1900N
Part Number 000014141 Rev 11 12/23
Section 2
Minimum
Maximum
ft
(cm
)
ft
(cm
3
3
3
0.020
0.030
(566)
(850)
0.045
0.060
(1274)
(1699)
0.085
0.105
(2407)
(2973)
Peak
Average
6900
6100
6900
6100
13900
9000
13700
12800
16000
13000
16000
13000
24500
20700
27000
23000
30500
26100
)
3