Monitoring and Troubleshooting
7-4
Table 7-1. Health and Status Messages (2 of 2)
Message
What Message Indicates
Mismatch Rate
The LTU, set to Fixed Rate
mode, is attempting to
operate at a DSL line
speed faster than the NTU
can handle.
Net Com Link Down
The Network
communication link is
down. Communications
between the management
system and the LTU/NTU
is not possible.
Net Margin
The signal-to-noise margin
Threshold
has exceeded the
configured threshold.
NTU/LTU Mismatch
The NTU is not configured
the same as the LTU.
NTU TS16 Not
The LTU is configured for
Supported
TS16 signaling and the
NTU is not configured to
support TS16 signaling.
OOF at Net
An OOF (Out Of Frame)
condition has been
detected at the network
interface.
Primary Clock Failed A failure has occurred in
the primary clock source
configured from the
Network, DSX, or from the
card internal clock.
RAI (Remote Alarm
A Remote Alarm Indication
Indication) at G.703
signal is being received by
interface, Pt 1
the G.703 interface.
SYNC Pt Down
The interchange circuits
for the DTE port are
configured to monitor DTR
and/or RTS, and a
monitored lead is not
asserted.
System Operational
There are no problems
detected.
Yellow Alarm at
A Yellow Alarm Indication
DSX-1
signal is being received by
the DSX-1 interface.
August 2000
What To Do
Set the LTU to a DSL line speed
available to the NTU.
1. Verify that the network cable is
securely attached at both ends.
2. Verify the link protocol for the
COM port is configured correctly.
3. Verify that no tests are active.
1. Reconfigure the unit to a higher
Net Margin Threshold.
2. Contact network provider.
Configure units to match.
1. Verify endpoint is a G.703
product. EIA-530-A products do
not support signaling.
2. Replace endpoint or reconfigure
TS16 to data.
Contact network provider.
1. Verify that the network cable is
securely attached at both ends.
2. Verify your clock configuration.
3. Contact network provider.
1. Verify that the units line framing
and line coding are compatible.
2. Contact network provider.
Verify that the DTE is providing the
monitored signals.
1. Verify that the units line framing
and line coding are compatible.
2. Contact network provider.