Paradyne 7974 User Manual page 112

M/sdsl standalone termination units
Table of Contents

Advertisement

Configuration Options
Table A-5. Synchronous Data Port Options for Model 7975 (3 of 3)
Action on Network LOS Alarm
Possible Settings: Halt, None
Default Setting: Halt
Specifies the action taken on the synchronous data port when an LOS (Loss Of Signal)
alarm is received on the network interface.
Halt – Stops the transmission of data on the data port and disables the data port when
an LOS alarm is received on the network interface. When LOS alarms are received, all
ones are sent on the Received Data interchange circuit BB (CCITT 104). The
Clear-to-Send interchange circuit CB (CCITT 106) is interrupted.
None – Makes the data port unaffected by LOS alarms received on the network
interface.
Network Initiated Data Channel Loopback
Possible Settings: Disable, Enable
Default Setting: Disable
Allows the initiation and termination of a Data Channel Loopback (DCLB) by the receipt
of a DCLB-actuate sequence or DCLB-release sequence from the network or far-end
device.
Disable – Ignores the DCLB-actuate and DCLB-release sequences for this port.
Enable – DCLB-actuate and DCLB-release sequences are recognized for this port.
Port (DTE) Initiated Loopbacks
Possible Settings: Disable, DTLB, DCLB, Both
Default Setting: Disable
Allows the initiation and termination of a local Data Terminal Loopback (DTLB) or
remote Data Channel Loopback (DCLB) by the DTE connected to this port. (DTLB is
equivalent to a V.54 loop 3, and DCLB is equivalent to a V.54 loop 2.) Control of these
loopbacks is through the DTE interchange circuits as specified by the V.54 standard.
Disable – Disables control of local DTLBs and remote DCLBs by the DTE connected to
this port.
DTLB – Gives control of the local DTLBs for this port to the DTE attached to this port.
This loopback is controlled by the Local Loopback interchange circuit LL (CCITT 141).
DCLB – Gives control of the remote DCLBs for the far-end port connected to this port to
the DTE attached to this port. This loopback is controlled by the Remote Loopback
interchange circuit RL (CCITT 140). The far-end equipment must support in-band
V.54 loopbacks.
Both – Gives control of local DTLBs and remote DCLBs to the DTE connected to this
port.
ElasticStore
Possible Settings: Disable, Enable
Default Setting: Enable
Used to enable or disable a first-in, first-out (FIFO) buffer circuit for the incoming
external clock. This circuit is used to compensate for the differences between the
frequencies of the data clocks for the two units in the circuit. This option only applies if
the unit is set for external timing. Do not enable Elastic Store if the attached DCE has
an elastic store buffer larger than 32 bits.
Disable – Disables the Elastic Store FIFO.
Enable – Enables the Elastic Store FIFO.
A-10
August 2000
7900-A2-GB21-00

Advertisement

Table of Contents
loading

This manual is also suitable for:

79757976Hotwire 7974-a2Hotwire 7975-a2Hotwire 7976-a2

Table of Contents