E. Sensors, switches, detectors
Code
Name
DFD
Original feed sensor
DTD
Original timing sensor
DED1
Original end sensor 1
DED2
Original end sensor 2
RDD
Original reverse sensor
DSD
Original set detector
DWS
Original width sensor
DFMRS
Paper feed motor
rotation sensor
DTMRS
Transport motor
rotation sensor
DLS1
Original length sensor 1
DLS2
Original length sensor 2
DWS1
Original width switch 1
DWS2
Original width switch 2
DWS3
Original width switch 3
DWS4
Original width switch 4
AUOD
ADF open/close switch
FGOD
Paper feed guide
open/close switch
TGOD
Reverse guide
open/close switch
DWS4
DWS3
AUOD
DWS2
DWS1
DFMRS
DED2
DSD
DWS
DFD
DTD
Type
Reflection sensor
Turns HIGH when the original lead edge is fed
just in front of the resist roller.
Reflection sensor
HIGH when the original lead edge is
transported from the paper feed section to the
vicinity of the transport belt.
Photo interrupter
Final paper sensor 1 on the tray
Reflection sensor
Final paper sensor 2 on the tray (AB series)
Reflection sensor
Turns HIGH when the original lead edge is
transported to the reverse/paper exit path.
Photo interrupter
Detects an original on the tray.
Photo interrupter
Senses the original width.
Photo interrupter
Senses the paper feed motor rotations.
Photo interrupter
Senses the transport motor rotations.
Photo interrupter
Senses the original length on the tray.
Photo interrupter
Senses the original length on the tray. (Inch
series only)
Lead switch
Senses the original width on the tray. (11",
297mm)
Lead switch
Senses the original width on the tray. (257mm,
AB series only)
Lead switch
Senses the original width on the tray. (8 1/2"
210mm)
Lead switch
Senses the original width on the tray. )182mm,
AB series only)
Microswitch
Senses the ADF unit open/close.
Microswitch
Senses the paper feed cover open/close.
Microswitch
Senses the reverse cover open/close.
DTMRS
DLS2
DLS1
DED1
RDD
TGOD
FGOD
Function, operation
– 6 –
Contact, output
HIGH when the original is
sensed.
HIGH when the original is
detected.
HIGH when the original is
sensed.
HIGH when the original is
sensed.
HIGH when the original is
sensed.
LOW when the original is
sensed.
HIGH when the original is
sensed.
Pulse output
Pulse output
HIGH when the original is
sensed.
HIGH when the original is
sensed.
ON when detected.
ON when detected.
ON when detected.
ON when detected.
Close when closed.
Close when closed.
Close when closed.

Advertisement