e. Remove the E ring, separator pulley drive gear and bearing
(w/one-way attachment), and slide the shaft in the direction of
arrow shown in the figure to remove it.
(Inch series)
To drive separator pulley
E ring
Bearing
(w/one-way attachment)
(AB series)
To drive separator pulley
Bearing
(w/one-way attachment)
E ring
f. Remove the spring which is hooked on the wait solenoid lever and
remove the E ring.
g. Unscrew the wait solenoid clamp screw and remove the plunger
from the lever.
(Inch series)
Rear bearing (Wait shaft)
Screw
Bearing
Lever
E ring
Spring
Wait solenoid
Rear side
plate
Rear side
plate
Screw
Screw
Empty sensor
BKT
Rear side plate
(AB series)
Rear bearing (Wait shaft)
Screw
Bearing
Lever
E ring
Wait solenoid
h. Remove the rear-side bearing of the wait shaft from the side plate.
i. Unscrew two screws to remove the empty sensor bracket.
<Note> For the AB series, remove the screw and the small
bracket.
j. Unscrew the screw to remove the open/close sensor lever brack-
et.
k. Unscrew four screws to remove the upper paper feed guide.
Open/close sensor
lever bracket
Screw
– 17 –
Screw
Screw
Empty sensor
BKT
Rear side plate
Screw
Upper paper feed
guide
Screw