Chapter 5 - Raid (Cs630-Q370 Only) - DFI CS630-Q370 User Manual

Atx industrial motherboard
Hide thumbs Also See for CS630-Q370:
Table of Contents

Advertisement

Chapter 5 - RAID (CS630-Q370 Only)

The system board allows configuring RAID on Serial ATA drives. It supports RAID 0, RAID 1,
RAID 5 and RAID 10.
RAID Levels
RAID 0 (Striped Disk Array without Fault Tolerance)
RAID 0 uses two new identical hard disk drives to read and write data in parallel, interleaved
stacks. Data is divided into stripes and each stripe is written alternately between two disk
drives. This improves the I/O performance of the drives at different channel; however it is not
fault tolerant. A failed disk will result in data loss in the disk array.
RAID 1 (Mirroring Disk Array with Fault Tolerance)
RAID 1 copies and maintains an identical image of the data from one drive to the other drive.
If a drive fails to function, the disk array management software directs all applications to the
other drive since it contains a complete copy of the drive's data. This enhances data protection
and increases fault tolerance to the entire system. Use two new drives or an existing drive and
a new drive but the size of the new drive must be the same or larger than the existing drive.
RAID 5
RAID 5 stripes data and parity information across hard drives. It is fault tolerant and provides
better hard drive performance and more storage capacity.
RAID 10 (Mirroring and Striping)
RAID 10 is a combination of data striping and data mirroring providing the benefits of both
RAID 0 and RAID 1. Use four new drives or an existing drive and three new drives for this
configuration.
RAID Level
Min. Drives
Protection
RAID 0
2
None
RAID 1
2
Single Drive Failure
RAID 5
3
Single Drive Failure
1 Disk Per Mirrored
RAID 10
4
Stripe (not same mirror)
Chapter 5 RAID
Chapter 5
Description
Data striping without redundancy
Disk mirroring
Block-level data striping with
distributed parity
Combination of RAID 0 (data striping)
and RAID 1 (mirroring)
62
Settings
To enable the RAID function, the following settings are required.
1. Connect the Serial ATA drives.
2. Enable RAID in the AMI BIOS.
3. Create a RAID volume.
4. Install the Intel Rapid Storage Technology Utility.
Step 1: Connect the Serial ATA Drives
Refer to chapter 2 for details on connecting the Serial ATA drives.
Important:
1. Make sure you have installed the Serial ATA drives and connected the data cables
otherwise you won't be able to enter the RAID BIOS utility.
2. Treat the cables with extreme caution especially while creating RAID. A damaged
cable will ruin the entire installation process and operating system. The system will
not boot and you will lost all data in the hard drives. Please give special attention
to this warning because there is no way of recovering back the data.
Step 2: Enable RAID in the AMI BIOS
1. Power-on the system then press <Del> to enter the main menu of the AMI BIOS.
2. Go to "Chipset" menu and select the "PCH-IO Configuration" menu then "SATA And RST
Configuration" menu.
3. Change the "SATA Mode Selection" to "Intel RST Premium With Intel Optane System Ac-
celeration" mode.
4. Press F10 to save the changes.
5. Reboot the system.