DFI CS631-C246 User Manual

Atx industrial motherboard
Hide thumbs Also See for CS631-C246:
Table of Contents

Advertisement

Quick Links

CS631-C246/Q370
ATX Industrial Motherboard
User's Manual
A51110951
Preliminary
Preliminary
Version
Version

Advertisement

Table of Contents
loading

Summary of Contents for DFI CS631-C246

  • Page 1 CS631-C246/Q370 ATX Industrial Motherboard User’s Manual Preliminary Preliminary Version Version A51110951...
  • Page 2 Copyright FCC and DOC Statement on Class B This publication contains information that is protected by copyright. No part of it may be repro- This equipment has been tested and found to comply with the limits for a Class B digital duced in any form or by any means or used to make any transformation/adaptation without the device, pursuant to Part 15 of the FCC rules.
  • Page 3: Table Of Contents

    External COM port Module ........................29 Chapter 3 - BIOS Settings ............................30 Chapter 1 - Introduction ..............................6 Overview ..................................30 Main ....................................30 Specifications ................................6 Advanced .................................30 CS631-C246 ................................6 RC ACPI Configuration ..........................31 CS631-Q370 ................................7 CPU Configuration ............................31 Features ..................................8 Power & Performance ..........................32 DDR4 ..................................8 PCH-FW Configuration ..........................32...
  • Page 4 About this Manual Static Electricity Precautions This manual can be downloaded from the website, or acquired as an electronic file included in It is quite easy to inadvertently damage your PC, system board, components or devices even the optional CD/DVD. The manual is subject to change and update without notice, and may be before installing them in your system unit.
  • Page 5 If you are installing the system board in a new system, you will need at least the following inter- please contact your dealer or sales representative for assistance. nal components. • One CS631-C246/CS631-Q370 board • • One COM port cable (Length: 300mm, 2 x DB9 ports) •...
  • Page 6 REAR I/O Ethernet 2 x GbE (RJ-45) X Specifications 2 x USB 3.1 Gen2 2 x USB 3.1 Gen1 2 x USB 2.0 CS631-C246 Serial 1 x RS-232/422/485 (RS-232 w/ power) (DB-9) PS/2 1 x PS/2 (mini-DIN-6) SYSTEM Processor 8th Generation Intel® Core...
  • Page 7 Chapter 1 INTRODUCTION Specifications CS631-Q370 INTERNAL I/O Serial 1 x RS-232/422/485 (RS-232 w/ power) (2.54mm pitch) 4 x RS-232 (2.54mm pitch) 2 x USB 3.1 Gen 1 (2.00mm pitch) SYSTEM Processor 8th Generation Intel Core /Pentium /Celeron Processors, LGA 1151 ®...
  • Page 8 Chapter 1 INTRODUCTION X Features Watchdog Timer PCI Express The Watchdog Timer function allows your application to regularly “clear” the system at the set PCI Express is a high bandwidth I/O infrastructure that possesses the ability to scale speeds time interval. If the system hangs or fails to function, it will reset at the set time interval so that by forming multiple lanes.
  • Page 9 Chapter 2 HARDWARE INSTALLATION Chapter 2 - Hardware Installation X Board Layout Note: The USB 11/12 ports can either be a 10-pin header or a vertical Type A connector. DDR4_1 DDR4_3 USB 2.0 System Fan 1 (USB 7/8) PS/2 KB/MS +12V Power Important: COM 1...
  • Page 10 Dual Channel DIMMs of the same memory configuration are on different channels. Step 1 Features • CS631-C246: Four 288-pin ECC/Non-ECC DIMM up to 64GB • CS631-Q370: Four 288-pin DIMM up to 64GB • Dual Channel DDR4 2400/2666 MHz Step 2...
  • Page 11 Chapter 2 HARDWARE INSTALLATION System Memory Installing the DIMM Module System Memory Removing the DIMM Module Please follow the steps below to install the memory card into the socket. Please follow the steps below to remove the memory card from the socket. Step 1: DDR4 DIMM DDR4 DIMM...
  • Page 12: Chapter 1 - Introduction

    Chapter 2 HARDWARE INSTALLATION X CPU Installing the CPU Make sure the PC and all other peripheral devices connected to it have been powered down. The system board is equipped with a surface mount LGA 1151 socket. This socket is exclu- sively designed for installing a LGA 1151 packaged Intel CPU.
  • Page 13: Cs631-Q370

    Chapter 2 HARDWARE INSTALLATION Installing the CPU Installing the CPU Load lever Lift the load lever and the load 7-2. Two keys on the sock- plate all the way up as shown in et and notches on the Alignment key C P U a l s o f a c i l i t a t e the photo.
  • Page 14: Features

    Chapter 2 HARDWARE INSTALLATION Installing the Fan and Heat Sink Screw tight two of the spring screws at opposite corners into the mounting holes. And The CPU must be kept cool by using a CPU fan with heat sink. Without sufficient air circula- then proceed with the other two spring screws.
  • Page 15: System Memory

    Chapter 2 HARDWARE INSTALLATION COM 1 Serial Mode X Jumper Settings Clear CMOS „ COM 1 JP1, JP2, and JP3 are used to configure the COM 1 port to RS232, RS422 (Full Duplex) or RS485. The three jumpers must all be configured to the same serial mode. If any anomaly of the followings is encountered —...
  • Page 16: Removing The Dimm Module

    Chapter 2 HARDWARE INSTALLATION Jumper Settings Jumper Settings COM 2 Serial Mode COM1 & COM2 RS232 Power Select JP10 „ COM 2 JP6, JP8, and JP10 are used to configure the COM 2 port to RS232, RS422 (Full Duplex) or Two COM ports support RS232 with or without power configured via jumper settings of JP4 RS485.
  • Page 17: Cpu

    Chapter 2 HARDWARE INSTALLATION Jumper Settings Jumper Settings Digital I/O (DIO) Power Select Digital I/O (DIO) Power Supply JP18 JP17 JP19 JP17 is used to select the power of Digital I/O: +5VDU (default) or +5V. The Digital I/O can be configured to use the power bus of the Digital I/O connector for power supply or not.
  • Page 18 Chapter 2 HARDWARE INSTALLATION Jumper Settings Jumper Settings Mini PCIe 2 Signal Select mSATA (Mini PCIe 2 connector) / 7-pin SATA (SATA4) Switch JP23 JP21 The signal of Mini PCIe 2 can be switched between SATA (default) or PCIe via JP23. When The Mini PCIe 2 bus is shared by a SATA bus and a PCIe bus.
  • Page 19: Installing The Fan And Heat Sink

    Chapter 2 HARDWARE INSTALLATION Jumper Settings Mini PCIe 2 Power Select JP22 The power of Mini PCIe 2 can be switched between 3V3DU and 3V3 via JP22. „ 1-2 On: 3V3DU (default) „ 2-3 On: 3V3 User's Manual | CS631...
  • Page 20: Jumper Settings

    Chapter 2 HARDWARE INSTALLATION Rear I/O Ports X Rear I/O Ports PS/2 Keyboard/Mouse „ PS/2 KB/MS „ COM „ LAN 1 „ LAN 2 „ Audio „ 2 x DP++ „ PS/2 KB/MS „ 2 x USB 2.0 „ VGA „...
  • Page 21: Com 2 Serial Mode

    Chapter 2 HARDWARE INSTALLATION Rear I/O Ports Rear I/O Ports USB Ports Graphics Display „ USB 8 (USB 2.0) „ USB 7 (USB 2.0) „ VGA „ DP++ 2 „ DP++ 1 „ USB 2 (USB 3.1 Gen 1) „ USB 4 (USB 3.1 Gen 2) The VGA port is used for connecting a VGA monitor.
  • Page 22: Digital I/O (Dio) Power Select

    Chapter 2 HARDWARE INSTALLATION Rear I/O Ports Rear I/O Ports RJ45 LAN Audio „ LAN 1 „ LAN 2 „ Line-out „ Mic-in The two LAN ports allow the system board to connect to a local area network. The system board is equipped with three rear audio jacks: BIOS Setting •...
  • Page 23: Mini Pcie 2 Signal Select

    Chapter 2 HARDWARE INSTALLATION Rear I/O Ports COM 1 (Serial) Port „ COM 1 „ COM 1 Pin Assignment Standard RS232 RS422 RS485 RS232 with Power DCD- +12V TXD- Data- TXD+ Data+ RXD+ N.C. DTR- DTR- RXD- N.C. DSR- DSR- N.C.
  • Page 24: Mini Pcie 2 Power Select

    Chapter 2 HARDWARE INSTALLATION X Internal I/O Connectors COM (Serial) Port „ COM Port Pin Assignment Standard RS232 with RS422 RS485 RS232 Power (COM 2) (COM 2) (COM 2) DCD- +12V TXD- Data- TXD+ Data+ RXD+ N.C. DTR- DTR- RXD- N.C.
  • Page 25: Internal I/O Connectors

    Chapter 2 HARDWARE INSTALLATION Internal I/O Connectors USB Ports „ USB (USB 2.0) Pin Assignment „ USB 3.1 Pin Assignment „ USB 5/6 (USB 3.1 Gen 1) Over Current Protection „ USB 9/10 (left), 11/12 (right) (USB 2.0) The USB device allows data exchange between your computer and a wide range of simultane- Note: ously accessible external Plug and Play peripherals.
  • Page 26: Usb Ports

    Chapter 2 HARDWARE INSTALLATION Internal I/O Connectors Internal I/O Connectors Front Audio SATA (Serial ATA) SATA0 „ Front Audio SATA1 SATA2 SATA3 SATA4 The Front Audio internal connector allows you to connect to the second line-out and mic-in The Serial ATA (SATA) connectors are used to connect the Serial ATA device. SATA 3.0 is sup- jacks that are at the front panel of your system.
  • Page 27: Front Audio

    Chapter 2 HARDWARE INSTALLATION Internal I/O Connectors Internal I/O Connectors Digital I/O Cooling Fan Connectors System Fan 1 (left), CPU Fan (right) „ System Fan 1/2/3 „ CPU Fan (PWM) „ Digital I/O System Fan 3 System Fan 2 The 8-bit Digital I/O (DIO) connector allows for input/output signals of digital logical states de- fined by voltage levels.
  • Page 28: Digital I/O

    Chapter 2 HARDWARE INSTALLATION Internal I/O Connectors Internal I/O Connectors Power Connector Chassis Intrusion „ ATX 24-pin Power Connector 12 24 +3.3V +12V +12V +12V +5VSB „ ATX 8-pin Power PWR_OK Connector PS_ON# „ Chassis Intrusion +3.3V -12V +3.3V +3.3V 1 13 Use a power supply that complies with the ATX12V Power Supply Design Guide Version 1.1.
  • Page 29: Power Connector

    Chapter 2 HARDWARE INSTALLATION Internal I/O Connectors Internal I/O Connectors Front Panel S/PDIF PWR-LED HD-LED RESET ATX-SW „ S/PDIF Connector 11 12 „ Front Panel Connector „ Front Panel Pin Assignment Assignment Assignment N.C. LED Power The Sony/Philips Digital Interface (S/PDIF) connector is for audio output to external audio equipment.
  • Page 30: Front Panel

    Chapter 2 HARDWARE INSTALLATION Internal I/O Connectors Internal I/O Connectors Battery SMBus „ Battery Holder „ SMBus The lithium ion battery addendum supplies power to the real-time clock and CMOS memory The SMBus (System Management Bus) connector is used to connect the SMBus device. It is a as an auxiliary source of power when the main power is shut off.
  • Page 31: Battery

    Chapter 2 HARDWARE INSTALLATION Internal I/O Connectors Internal I/O Connectors LAN LED Expansion Slots M.2 M Key Mini PCIe 2 „ LAN LED Connector Mini PCIe 1 The LAN LED connector is used to detect the connection state of RJ45 LAN ports when the M.2 Sockets connection is made to an active network via a cable.
  • Page 32: Lan Led

    Chapter 2 HARDWARE INSTALLATION Internal I/O Connectors Expansion Slots Installing the M.2 Module Before installing the M.2 module into the M.2 socket, please make sure that the following Please follow the steps below to install the card into the socket. safety cautions are well-attended.
  • Page 33: Installing The M.2 Module

    Chapter 2 HARDWARE INSTALLATION Internal I/O Connectors Expansion Slots Installing the Mini PCIe Module Please follow the steps below to install the card into the socket. Before installing the Mini PCIe module into the Mini PCIe socket, please make sure that the fol- lowing safety cautions are well-attended.
  • Page 34: External Com Port Module

    External COM port Module The LPC connector is used for debugging. The external COM port modules — EXT-RS232 and EXT-RS485 — are designed by DFI’s propri- etary technology, and support four additional COM ports per module. The EXT-RS232/RS485 card is connected to the motherboard via the LPC connector and secured by a standoff as il- lustrated below.
  • Page 35: Chapter 3 - Bios Settings

    Chapter 3 BIOS SETTINGS Chapter 3 - BIOS Settings Legends X Overview The BIOS is a program that takes care of the basic level of communication between the CPU Keys Function and peripherals. It contains codes for various advanced features found in this system board. The BIOS allows you to configure the system and save the configuration in a battery-backed Right / Left arrow Move the highlight left or right to select a menu...
  • Page 36: Main

    Chapter 3 BIOS SETTINGS X Main X Advanced The Main menu is the first screen that you will see when you enter the BIOS Setup Utility. The Advanced menu allows you to configure your system for basic operation. Some entries are defaults required by the system board, while others, if enabled, will improve the performance of your system or let you set some features according to your preference.
  • Page 37: Rc Acpi Configuration

    Chapter 3 BIOS SETTINGS Advanced Advanced RC ACPI Configuration CPU Configuration Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Advanced Advanced CPU Configuration When enabled, a VMM can RC ACPI Configuration Enable or disable System utilize the additional hard-...
  • Page 38: Power & Performance

    Chapter 3 BIOS SETTINGS Advanced Advanced Power & Performance PCH-FW Configuration Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Advanced Advanced ME State [Enabled] When Disabled ME will be Power &...
  • Page 39 Chapter 3 BIOS SETTINGS Advanced PCH-FW Configuration Advanced PCH-FW Configuration ► AMT Configuration ► AMT Configuration ► Secure Erase Configuration Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Advanced Advanced USB Provisioning of AMT...
  • Page 40 Chapter 3 BIOS SETTINGS Advanced PCH-FW Configuration Advanced PCH-FW Configuration ► AMT Configuration ► OEM Flags Settings ► Firmware Update Configuration Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Advanced Advanced Me FW Image Re-Flash...
  • Page 41: Trusted Computing

    Chapter 3 BIOS SETTINGS Advanced Advanced Trusted Computing NCT6116D Super IO Configuration Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Advanced Advanced TPM20 Device Found Enables or Disables BIOS NCT6116D Super IO Configuration WatchDog Timer Unit Se- Firmware Version...
  • Page 42: Nct6116D Hw Monitor

    Chapter 3 BIOS SETTINGS Advanced NCT6116D Super IO Configuration Advanced ► Serial Port 1/2/3/4/5/6 Configuration NCT6116D HW Monitor Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Advanced Advanced Serial Port 1 Configuration Enable or Disable Serial Smart Fan function setting...
  • Page 43: Serial Port Console Redirection

    Chapter 3 BIOS SETTINGS Advanced NCT6116D HW Monitor Advanced ► Smart Fan Function Serial Port Console Redirection Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Advanced Advanced Enable CPU SmartFan Console Redirection En - Smart Fan Function COM1...
  • Page 44: Usb Configuration

    Chapter 3 BIOS SETTINGS Advanced Serial Port Console Redirection Advanced ► Console Redirection Settings USB Configuration Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Advanced Advanced Enable CPU SmartFan Enables Legacy USB sup- COM1 USB Configuration...
  • Page 45: Network Stack Configuration

    Chapter 3 BIOS SETTINGS Advanced Advanced Network Stack Configuration CSM Configuration Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Advanced Advanced Enable/Disable UEFI Net- Enable/Disable CSM Sup- Network Stack [Enabled] Compatibility Support Module Configuration work Stack...
  • Page 46: Chipset

    Chapter 3 BIOS SETTINGS Chipset X Chipset Graphics Configuration Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Main Advanced Chipset Security Boot Save & Exit Chipset ► Graphics Configuration Initial priority : Graphics Configuration Graphics Configuration...
  • Page 47: Peg Port Configuration

    Chapter 3 BIOS SETTINGS Chipset Chipset PEG Port Configuration PCH-IO Configuration Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Chipset Chipset Enable or Disable the Root PCI Express Configuration PEG Port Configuration PCH-IO Configuration Port...
  • Page 48: Sata And Rst Configuration

    Chapter 3 BIOS SETTINGS Advanced Chipset PCH-IO Configuration SATA And RST Configuration PCI Express Configuration Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Chipset Chipset SATA And RST Configuration E n a b l e o r d i s a b l e S ATA PCI Express Root Port Set- PCI Express Configuration...
  • Page 49: Hd Audio Configuration

    Chapter 3 BIOS SETTINGS Chipset PCH-IO Configuration HD Audio Configuration Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Chipset Control Detection of the HD Audio Subsystem Confi guration Settings HD-Audio device. Disabled = HDA will be un- HD Audio [Enabled] conditionally disabled Enabled = HDA will be un-...
  • Page 50: Security

    Chapter 3 BIOS SETTINGS Security X Security Secure Boot Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Main Advanced Chipset Security Boot Save & Exit Security Password Description S e t A d m i n i s t r a t o r P a s s - System Mode Setup...
  • Page 51 Chapter 3 BIOS SETTINGS Security Secure Boot X Key Management • “PK” for Platform Keys Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Security • “KEK” for Key Exchange Keys Factory Key Provision [Disabled] Provision factory default keys on next re-boot only •...
  • Page 52: Boot

    Chapter 3 BIOS SETTINGS X Boot X Save & Exit Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc. Main Advanced Chipset Security Boot Save & Exit Main Advanced Chipset Security Boot...
  • Page 53: Updating The Bios

    BIOS with the flash utility. For updating AMI BIOS in UEFI mode, you may refer to the how-to video at https://www.dfi.com/Knowledge/Video/5. X Notice: BIOS SPI ROM 1.
  • Page 54: Chapter 4 - Intel Amt Settings

    Chapter 4 INTEL AMT SETTINGS Chapter 4 - Intel AMT Settings X Enable Intel AMT in the AMI BIOS ® Power-on the system then press <Del> to enter the main menu of the AMI BIOS. X Overview In the Advanced menu, select PCH-FW Configuration. Intel Active Management Technology (Intel AMT) combines hardware and software solution to ®...
  • Page 55: Entering Management Engine Bios Extension (Mebx)

    Chapter 4 INTEL AMT SETTINGS Enable Intel AMT in the AMI BIOS ® X Entering Management Engine BIOS Extension (MEBX) Press F4, or go to the Save & Exit menu, select Save Changes and Reset and then press <Enter>. A dialog box will appear. Select Yes and press Enter to reset the system after saving all changes made.
  • Page 56: Mebx

    Chapter 4 INTEL AMT SETTINGS X MEBX Intel(R) ME General Settings Main Menu Select MEBx Login under Main Menu and press Enter. A prompt that requires password input Select Intel(R) ME General Settings under Main Menu and then press Enter. will show up.
  • Page 57 Chapter 4 INTEL AMT SETTINGS MEBX Intel(R) ME General Settings MEBX Intel(R) ME General Settings Change ME Password Local FW Update If you want to change ME password, select Change ME Password and then press Enter. A Select Local FW Update then press Enter. Select Enabled or Disabled or Password Protected prompt that requires password input will show up.
  • Page 58: Intel(R) Amt Configuration

    Chapter 4 INTEL AMT SETTINGS MEBX > SOL/Storage Redirection/KVM Intel(R) AMT Configuration Select Intel(R) AMT Configuration under Main Menu and then press Enter. Intel(R) Management Engine BIOS Extension v11.0.0.0010/Intel(R) ME v11.8.55.3510 Intel(R) Management Engine BIOS Extension v11.0.0.0010/Intel(R) ME v11.8.55.3510 Copyright(C) 2003-16 Intel Corporation. All Rights Reserved Copyright(C) 2003-16 Intel Corporation.
  • Page 59 Chapter 4 INTEL AMT SETTINGS MEBX Intel(R) AMT Configuration MEBX Intel(R) AMT Configuration > SOL/Storage Redirection/KVM > User Consent Intel(R) Management Engine BIOS Extension v11.0.0.0010/Intel(R) ME v11.8.55.3510 Intel(R) Management Engine BIOS Extension v11.0.0.0010/Intel(R) ME v11.8.55.3510 Copyright(C) 2003-16 Intel Corporation. All Rights Reserved Copyright(C) 2003-16 Intel Corporation.
  • Page 60 Chapter 4 INTEL AMT SETTINGS MEBX Intel(R) AMT Configuration MEBX Intel(R) AMT Configuration > User Consent Password Policy Intel(R) Management Engine BIOS Extension v11.0.0.0010/Intel(R) ME v11.8.55.3510 Intel(R) Management Engine BIOS Extension v11.0.0.0010/Intel(R) ME v11.8.55.3510 Copyright(C) 2003-16 Intel Corporation. All Rights Reserved Copyright(C) 2003-16 Intel Corporation.
  • Page 61 Chapter 4 INTEL AMT SETTINGS MEBX Intel(R) AMT Configuration > Network Setup Move the cursor to select a field and press Enter to display options. Under the Intel(R) AMT Configuration menu, select Network Setup and then press Enter. Intel(R) Management Engine BIOS Extension v11.0.0.0010/Intel(R) ME v11.8.55.3510 Intel(R) Management Engine BIOS Extension v11.0.0.0010/Intel(R) ME v11.8.55.3510 Copyright(C) 2003-16 Intel Corporation.
  • Page 62 Chapter 4 INTEL AMT SETTINGS MEBX Intel(R) AMT Configuration Network Setup Intel(R) ME Network Name Settings MEBX Intel(R) AMT Configuration Network Setup Dynamic DNS Update > TCP/IP Settings Select Enabled or Disabled then press Enter. When Dynamic DNS Update is Enabled, the follow- Under the Intel(R) ME Network Setup menu, select TCP/IP Settings and then press Enter.
  • Page 63 Chapter 4 INTEL AMT SETTINGS MEBX Intel(R) AMT Configuration Network Setup TCP/IP Settings DHCP Mode IPv4 Address Select Enabled or Disabled then press Enter. Please make sure there is a DHCP server in the Assign a valid and available IP address to the system. Insert a value from 0.0.0.0 to network when this field is enabled.
  • Page 64 Chapter 4 INTEL AMT SETTINGS MEBX Intel(R) AMT Configuration MEBX Intel(R) AMT Configuration Activate Network Access Unconfigure Network Access Under the Intel(R) AMT Configuration menu, select Activate Network Access and press Enter, Under the Intel(R) AMT Configuration menu, select Undconfigure Network Access and press and then press Y to activate the ME network connection with the settings configured previ- Enter, and then press Enter to fully deactivate the ME network connection and reset configura- ously, or press N to abort.
  • Page 65 Chapter 4 INTEL AMT SETTINGS MEBX Intel(R) AMT Configuration > Remote Setup And Configuration Under the Intel(R) AMT Configuration menu, select Remote Setup And Configuration then Current Provisioning Mode press Enter. The current mode — Public Key Infrastructure (PKI) — is displayed. Intel(R) Management Engine BIOS Extension v11.0.0.0010/Intel(R) ME v11.8.55.3510 Copyright(C) 2003-16 Intel Corporation.
  • Page 66 Chapter 4 INTEL AMT SETTINGS MEBX Intel(R) AMT Configuration Remote Setup And Configuration MEBX Intel(R) AMT Configuration Remote Setup And Configuration > RCFG > TLS PKI Press Enter, select Start Configuration, and then press Enter to activate Remote Configuration The system adopts PKI for encryption and authentication, and the TLS protocol for communica- (RCFG).
  • Page 67 Chapter 4 INTEL AMT SETTINGS MEBX Intel(R) AMT Configuration Remote Setup And Configuration TLS PKI MEBX Intel(R) AMT Configuration > Power Control Under the Intel(R) AMT Configuration menu, select Power Control then press Enter. > Manage Hashes Intel(R) Management Engine BIOS Extension v11.0.0.0010/Intel(R) ME v11.8.55.3510 Select a hash name and then press the following keys to execute a function.
  • Page 68 Chapter 4 INTEL AMT SETTINGS MEBX MEBx Exit Under the Main Menu, select MEBx Exit and then press Enter. Press Y to confirm or N to abort. Intel(R) Management Engine BIOS Extension v11.0.0.0010/Intel(R) ME v11.8.55.3510 Copyright(C) 2003-16 Intel Corporation. All Rights Reserved MAIN MENU >...
  • Page 69: Chapter 5 - Raid

    Chapter 5 RAID Chapter 5 - RAID X Setup Procedure The system board allows configuring RAID on Serial ATA drives. It supports RAID 0, RAID 1, RAID 5 and RAID 10. To enable the RAID function, the following settings are required. X RAID Levels Install SATA drives.
  • Page 70 Chapter 5 RAID Step 3: Create a RAID Volume Step 4: Install the Intel Rapid Storage Technology Utility Go to the “Advanced” menu of the AMI BIOS and select “Intel(R) Rapid Storage Technol- The Intel Rapid Storage Technology Utility can be installed from within Windows. It allows RAID ogy”.
  • Page 71: Chapter 6 - Supported Software

    You may acquire the software from your sales representa- the Intel chipset can be recognized and configured properly in the system. tives, from an optional DVD included in the shipment, or from the website download page at https://www.dfi.com/DownloadCenter. Setup is ready to install the util- X Auto-run Menu ity.
  • Page 72: Intel Hd Graphics Drivers

    Chapter 6 SUPPORTED SOFTWARE X Intel HD Graphics Drivers Go through the readme docu- ment for more installation tips then click “Install”. Setup is now ready to install t h e g r a p h i c s d r i v e r. C l i c k “Next”.
  • Page 73: Realtek Audio Drivers

    Chapter 6 SUPPORTED SOFTWARE X Realtek Audio Drivers Go through the readme docu- ment for system requirements and installation tips then click “Next”. Setup is ready to install the driver. Click “Next”. Setup is now installing the driver. Click “Next” to continue. Click “Yes, I want to restart my computer now”...
  • Page 74: Intel Lan Driver

    Chapter 6 SUPPORTED SOFTWARE X Intel LAN Driver Click “Install” to begin the in- stallation. Setup is ready to install the driver. Click “Next”. The step displays the installing status in the progress. Click “I accept the terms in the license agreement”...
  • Page 75: Intel Me Drivers

    Chapter 6 SUPPORTED SOFTWARE X Intel ME Drivers Click “Next” to install to the Setup is ready to install the default folder, or click “Change” driver. Click “Next”. to choose another destination folder. Please wait while the product Read the license agreement is being installed.
  • Page 76: Intel Serial Io Drivers

    Chapter 6 SUPPORTED SOFTWARE X Intel Serial IO Drivers Go through the readme docu- 1. Setup is ready to install the ment for system requirements driver. Click “Next”. and installation tips then click “Next”. 2. Read the license agreement carefully. Tick “I accept the terms in the 4.
  • Page 77: Intel Rapid Storage Technology

    Chapter 6 SUPPORTED SOFTWARE X Intel Rapid Storage Technology The Intel Rapid Storage Technology is a utility that allows you to monitor the current status 5. Setup is now installing the driver. of the SATA drives. It enables enhanced performance and power management for the storage subsystem.
  • Page 78 Chapter 6 SUPPORTED SOFTWARE Go through the readme docu- Click “Yes, I want to restart this ment to view system require- computer now” to complete the ments and installation informa- installation and then click “Fin- tion then click “Next”. ish”. Click “Next”...
  • Page 79: Adobe Acrobat Reader 9.3

    Chapter 6 SUPPORTED SOFTWARE X Adobe Acrobat Reader 9.3 Click “Next” to install or click 3. Setup is now installing the driver. “Change Destination Folder” to select another folder. Click “Install” to begin installa- Click “Finish” to exit installa- tion. tion.

This manual is also suitable for:

Cs631-q370Cs631-c246crmCs631-q370crm

Table of Contents