Troubleshooting

Problem
The battery backup outlets 8
1
are not supplied with power.
2
The connected devices are not
supplied when AC power fails.
3
AC power is available, but the
UPS operates on battery power.
The filtered outlets 7 are not
4
supplied.
Green button 11 flashes
5
frequently and audio alarm beeps
every 5 secondes.
Green button 11 flashes
6
frequently and audio alarm is
continuous.
Red LED 10 is on and the
7
audio alarm beeps every 30
seconds.
Green LED 9 is off and the
8
filtered outlets 7 are supplied.
9
The telephone line is disturbed
or modem access is not possible.
Red LED 10 is ON.
10
Advanced customizing of your UPS:
Sensitivity to variations of the AC power supply
Only to be used if frequent switching to the UPS battery
due to large variations in the AC supply voltage.
Accessing the programming mode: with the device
switched off, press button 11 for 6 s and release it once
LEDs 10 11 9 have come on.
Display of the 3 possible voltage ranges according to the
status of LEDs 10 and 11 :
Normal mode
Low range
(factory
mode:
configuration):
AC supply
AC supply
between 160V
between 184V
and 264V
and 264V
10 = ON 11 = ON
10 = ON 11 = OFF 10 = OFF 11 = ON
10 11 9
10 11 9
Change from one mode to another by
successively pressing button 11 .
Memorizing the mode: 10 s after the last press of the
button.
6
Diagnostic
Button 11 is not pressed.
The devices are not connected to
the battery backup outlets 8 .
Circuit breaker 12 has been tripped
by an overload on the UPS output.
The wall outlet is not supplied.
Circuit breaker 12 has been tripped
by an overload on the UPS output.
The UPS frequently operates on
battery power because the AC power
source is of poor quality.
The UPS battery backup outlets 8
are overloaded.
A fault has occurred on the UPS.
The battery backup outlets 8 are no
longer supplied.
Surge protection is no longer
provided.
Surge protection on the telephone
line is no longer provided.
The battery has reached the end of
its service life.
Audio alarm
Possibility of deactivating the audio alarm when the UPS
is operating on the battery.
Accessing the programming mode: with the device
switched off, press button 11 for 11 s and release it once
the audio alarm sounds.
Display of the 2 possible audio alarm modes:
Low and high
Normal mode (factory
range mode:
configuration):
AC supply
the UPS emits a beep every
between 160V
10 s when operating on its
and 284V
battery.
Normal mode
activated:
Buzzer emits long
beep.
10 11 9
Memorizing the mode: 10 s after the last press of the
button.
Solution
Press button 11 and check that it
turns green.
Connect the devices to the battery
backup outlets 8 .
Disconnect excess equipment and
reset the circuit breaker 12 by pressing
the corresponding button.
Supply power to the wall outlet.
Disconnect excess equipment and
reset the circuit breaker 12 by pressing
the corresponding button.
Have the electrical installation
checked by a professional or use
another wall outlet.
Disconnect excess equipment
connected to the battery backup outlets
8 .
Call after-sales support.
Call after-sales support.
Disconnect the telephone line from
the wall outlet.
Call after-sales support.
Have the battery replaced.
Silent mode:
the UPS emits a single
beep when switching to
battery operation and then
remains silent.
Silent mode
activated:
Buzzer emits
short beep.
Change from one mode to another by
successively pressing button 11 .