Resetting the Ground Fault Interrupt

This control panel is equipped with a ground fault
interrupt (GFPE) circuit breaker (Fig 6). If the discon-
nect switch is ON, but all lights on the electrical control
panel are off, have a qualified electrician check the
ground fault interrupt.
WARNING
ELECTROCUTION HAZARD
To reduce risk of injury or damage to
equipment, perform this procedure with
the main disconnect OFF.
GFPE
Fig. 6
Operation
TI0565
4-Zone Accessory Control
To reset the ground fault interrupt, have a qualified
electrician:
1. Turn OFF the electrical disconnect on the electrical
control panel.
2. Open the electrical control box and locate the
Ground Fault Interrupt switch (GFPE). The
ground fault interrupt will be in a "neutral" position,
between the ON and OFF positions.
3. Move the GFPE switch to the OFF position, then
move it to the ON position.
4. Close the door and turn ON the disconnect switch.
243699