Ground The System - Graco Therm-O-Flow Plus 243698 Instructions-Parts List Manual

Accessory heat zone controls
Table of Contents

Advertisement

Ground The System

Ground the supply unit as instructed here and in the
individual component manuals.
WARNING
FIRE, EXPLOSION, AND ELECTRIC
SHOCK HAZARD
To reduce the risk of fire, explosion, or
electric shock:
D The power source conduit is not an
adequate ground for the system. The
unit must be bonded to either the
building ground or a true earth
ground.
D A qualified electrician must complete
all grounding and wiring connections
and check the resistance as
instructed on page 12.
D Refer to your local code for the requirements for
a "true earth ground" in your area.
D Also read and follow the warnings on page 5.
10
309213
Installation
To reduce the risk of static sparking, ground the pump,
object being dispensed to, and all other spraying/dis-
pensing equipment used or located in the spraying/dis-
pensing area. Check your local electrical code for
detailed grounding instructions for your area and type
of equipment.
Fluid Hoses
Use only Therm-O-Flow Plus heated hoses and
accessories.
Dispensing/Spray Gun
Follow the dispensing/spray gun grounding instruc-
tions.
Object Material is Applied To
Ground the object according to your local code.
Material Drums
Ground the material drums according to your local
code. Use only metal drums placed on a grounded
surface. Do not place the drum on a nonconductive
surface, such as paper or cardboard, which interrupts
the grounding continuity.
Maintain Grounding Continuity When Purging Or
Relieving Pressure
Follow the instructions in your separate gun manual for
safely grounding your gun while purging.