Lincoln Electric Ranger Air 260MPX Operator's Manual page 13

Table of Contents

Advertisement

RANGER AIR 260MPX
®
Always disconnect the negative (-) battery cable before charging
the battery.
FIGURE A.2
Battery Cover
Battery
CABLE STRAIN RELIEF INSTALLATION
The welder's Strain Relief Kit accessory (K5322-1/not included
with the welder) includes 2 strain relief assemblies. The parts
are:
1/4-20 T30 Drive Button Head Screws (Qty 4)
Vibration Isolating Clamps (Qty 2)
Stainless Steel Shackle (Qty 2)
WARNING
Do not pull or lift the Ranger by the strain relief shackles.
To install:
1.
Obtain one isolator and one shackle. If the cord has a large
connector on the end, place the shackle around the cord at
this time. Thread the pin through the shackle and the rubber
part of the isolating clamp. It will be much easier to do this
step without the stainless steel strap over the rubber
grab the pin and prevent it from rattling loose. Repeat this
step again from the other side of the machine.
2.
Push a stainless steel strap over each rubber isolator as
3.
Route leads and power cords through the shackles as
shown.
4.
Using two 1/4-20 T30 button head screws, mount one
assembly as shown to each side of the front of the
Ranger. Tighten each T30 screw to 50 in.-lbs. For ease
of operation, position each shackle so that the shackle
pin head is pointed towards the outside of the machine,
as pictured below.
A-4
INSTALLATION

Advertisement

Table of Contents
loading

Table of Contents