Lincoln Electric Ranger Air 260MPX Operator's Manual page 35

Table of Contents

Advertisement

RANGER AIR 260MPX
®
BATTERY CHARGE PROCEDURE
1.
Stop the engine of machine connected to the battery.
2.
Disconnect the cables to the battery as required.
3.
Connect the jumper cables to the battery. Connect the
positive (+) cable to the positive (+) battery terminal,
and the negative (-) cable to the negative (-) battery
terminal.
4.
Plug the jumper cable into the Ranger Air.
---
Battery Type
12V Lead Acid
E
½
F
Connect cables to battery
Push to confirm
5.
Press the knob to begin charging. Charging will
continue for up to 45 minutes, or until the charge
voltage is reached.
6.
Press the knob, Home button or Back button to stop
charging at any time.
7.
Disconnect the cables to the battery as required.
8.
Connect the jumper cables to the battery. Connect the
positive (+) cable to the positive (+) battery terminal,
and the negative (-) cable to the negative (-) terminal.
9.
Plug the jumper cable into the Ranger Air.
10. Press the knob to begin charging. Charging will
continue for up to 45 minutes, or until the charge
voltage is reached.
11. Press the knob, Home button or Back button to stop
charging at any time.
---
12V Lead Acid
E
½
F
Rotate clockwise
To turn output ON
Ba ery Summary
Battery Action
25A Charging
ON
Ba ery Charge
25.0
A
12.0
V
OFF
Output
In some instances, a battery will not charge because the battery
voltage is too low. To attempt to charge the battery and override
the low battery voltage fault:
Press and hold the knob for 3 seconds.
The Ranger will attempt to charge the battery at 10
amps for up to 30 seconds.
Ba ery Low Voltage Override
---
12V Lead Acid
E
½
F
Press and hold
to charge
CAUTION
When overriding the low voltage fault, the jumper
cables must be connected for proper polarity and
must not be shorted together.
BATTERY JUMP ASSIST PROCEDURE
1.
Stop the engine of machine connected to the battery.
2.
Connect the jumper cables to the battery. Connect the
positive (+) cable to the positive (+) battery terminal,
and the negative (-) cable to the negative (-) battery
terminal.
3.
Plug the jumper cable into the Ranger Air.
---
Battery Type
12V Lead Acid
E
½
F
Connect cables to battery
B-14
OPERATION
48.1
A
6.2
V
ON
Output
Ba ery Summary
Battery Action
260A Jump Assist
ON
Push to confirm

Advertisement

Table of Contents
loading