For a positive-grounded vehicle, connect NEGATIVE
(BLACK) clip from battery charger to NEGATIVE (NEG,
N, -) ungrounded post of battery. Connect POSITIVE
(RED) clip to vehicle chassis or engine block away
from battery. Do not connect clip to carburetor, fuel
lines or sheet-metal body parts. Connect to a heavy
gage metal part of the frame of engine block.
See operating instructions for length of charge
information.
DC CONNECTION PRECAUTIONS, BATTERY
OUTSIDE OF A VEHICLE
• Check polarity of battery posts. Positive (POS, P, +)
battery post usually has a larger diameter than Negative
(NEG, N, -) post.
When disconnecting charger, always do so in reverse
connection while as far away from battery as practical.
A marine (boat) battery must be removed and charged
on shore. To charge it on board requires equipment
specially designed for marine use.
The Ranger cannot produce enough current to crank most
engines. If the engine does not crank, charge the battery for at
least 10 minutes before attempting jump assist again. If after
two attempts of charging/jump assist the engine does not start,
the batteries may require replacement.
Jump assist requires the vehicle having a battery. Do not attempt
to jump assist a vehicle without a battery or by connecting the
jumper cables directly to the starter. Damage to the vehicle may
occur.
NOTE:
• When using jump assist, the air compressor will be
turned off.
• Welding may not be performed while using battery
charge or jump assist
• Auxiliary power may not be used while use battery
charge or jump assist
BATTERY CHARGING
When charging, the engine rpm will remain at 2500 rpm.
When using jump assist, the engine rpm will start at 2500 rpm,
ramp to 3600 rpm, and then adjust as needed.
The Ranger Air is capable of charging and providing jump assist
to 12V and 24V batteries. Select the desired battery type and
press the knob.
---
E
½
F
Choose the desired action to perform on the battery.
25 amp charging
50 amp charging
260 amp jump assist
---
E
½
F
CAUTION
Do not leave the Ranger unattended when using
battery charge or jump assist.
and then to the Ranger.
To prevent damaging voltage spikes, the vehicle
battery cables must be disconnected from the
battery to be charged in any vehicle equipped
with a computer, or any vehicle or machine with
sensitive electronic components. Failure to
follow this warning can result in damage or failure
of any or all electronic components of the vehicle
or machine.
B-13
OPERATION
Ba ery Type
12V Lead Acid
24V Lead Acid
ON
Turn & Push to select
Ba ery Ac on
25A Charging
260A Jump Assist
ON
Turn & Push to select

Advertisement