LeCroy 9400A Manual page 69

Digital oscilloscope
Table of Contents

Advertisement

When in the main menu, pressing
RS-232-C
SETUP button (8) calls
interactive menu enabling configuration of both of the 9400A's RS-232-C
ports
for a particular
application.
Parameters
for
the
plotter-dedicated RS-232-C port (57) are displayed in the lower portion
of the screen,
while those for the remote
RS-232-C
port (56) are
presented in the upper portion of the screen.
I~wioue
VALUE
Nex~
RS~32 - RemOte c~nbrol port
Saud r'~e: !~
C~ro~er Length Cblt6):
Parity:
norm
Number oF stop bits: I
RS232 - Plotter port
Baud rate: 9600
Charooter Length Cblt~):
Parity:
none
Number oP etop bite: I
RS-232-C SETUP MENU
Figure 5.16
To modify any of the parameters displayed, first select the field to be
modified. The rectangular frame around parameter values indicates the
currently selected field. Pressing the Previous FIELD button (2) will
cause the frame to move towards the top of the list, whereas pressing
the Next FIELD button (3) will move the frame downwards.
Following
field
selection,
the current
value of the field may be
modified by pressing either the Previous (6) or Next VALUE (7).
Baud rate is selected from a set of values in the range ii0 through
19,200 baud. The possible settings of character length are 6, 7, and 8;
parity, none, even or odd; and number of stop bits, I and 2.