2N Indoor Talk User Manual page 44

Hide thumbs Also See for Indoor Talk:
Table of Contents

Advertisement

Remote Packet Capture
1.
Click
.
2.
A box will open for you to set the incoming/outgoing packet capturing time (in seconds).
3.
Click OK to start capture.
4.
Select a location on the disk for the packet capture file to be saved.
5.
Click
to stop capturing.
Syslog
2N Indoor Talk allows you to send system messages to the Syslog server including relevant information
on the device states and processes for recording and subsequent analysis and audit. It is unnecessary to
configure this service for common operations.
Syslog Server Settings
Send Syslog Messages – enable sending of syslog messages to the Syslog server. Make sure that the
server address is valid.
Server Address – set the "IP[:port]" or MAC address of the server on which the Syslog message capture
application is running.
Severity Level – set the severity level of the messages to be sent (Error, Warning, Notice, Info, Debug
1–3). Debug 1–3 level setting is only recommended to facilitate troubleshooting for the Technical Support
department.
Local Syslog Messages
This block provides a general overview of local Syslog messages. Local Syslog messages can be uploaded
and downloaded
Maintenance
This menu helps you maintain the device configuration and firmware. You can back up and restore all the
parameters, upgrade firmware and/or factory reset the device.
Configuration
Restore Configuration – restore configuration from a previous backup. Press the button to display a dialog
box to select a configuration file and upload it to the device. Before uploading choose whether or not the LAN
settings and SIP PBX connection settings are to be applied.
Backup Configuration – back up the complete current device configuration. Press the button to download
the complete configuration into a storage.
CAUTION
As the device configuration may include delicate information, such as user phone numbers
and access passwords, handle the file cautiously.
Reset Configuration – reset all the device parameters except for the LAN parameters. To reset the device
completely, use the appropriate jumper or press Reset.
System
Upgrade Firmware – upload a new firmware version to the device. Press the button to display a dialog
box and select the proper firmware file. Once the firmware is uploaded successfully, the device is restarted
Configuration
.
44