2N Indoor Talk User Manual page 42

Hide thumbs Also See for Indoor Talk:
Table of Contents

Advertisement

NOTE
• A certificate with a private RSA key longer than 2048 bits can be rejected. and the
following message will be displayed:
"The private key file/password was not accepted by the device!"
• For certificates based on elliptic curves use the secp256r1 (aka prime256v1 aka NIST
P-256) and secp384r1 (aka NIST P-384) curves only.
Auto Provisioning
My2N
The My2N cloud platform is used for remote administration and configuration of the 2N IP devices and helps
you remotely connect to the device web interface.
My2N Enabled – enable connection to My2N.
My2N Security Code
Serial Number – display the serial number of the device to which the valid My2N code applies.
My2N Security Code – device code for adding to My2N.
Generate New – the active My2N Security Code will be invalidated and a new one will be generated.
Connection State
It displays information on the state of the device connection to My2N.
My2N ID – unique identifier of the company created via the My2N portal.
TR069
Use this tab to enable and configure remote device management via the TR-069 protocol. TR-069 helps you
reliably configure the device parameters, update and back up configuration and/or upgrade device firmware.
The TR-069 protocol is utilized by the My2N cloud service. Make sure that TR-069 is enabled and Active
profile set to My2N to make the device work with My2N properly. Only then the device will be able to log in to
My2N periodically for configuration.
This function helps you connect the device to your ACS (Auto Configuration Server). In this case, the
connection to My2N will be disabled in the device.
My2N / TR069 Enabled – enable connection to My2N or another ACS server.
General Settings
Active Profile – select one of the pre-defined profiles (ACS), or choose a setting of your own and configure
the ACS connection manually.
Next Synchronization in – display the time period in which the device shall contact a remote ACS.
Connection Status – display the current ACS connection state or error state description if necessary.
Communication Status Detail – server communication error code or HTTP status code.
Connection test – test the TR069 connection according to the set profile, see the Active profile. The test
result is displayed in the Connection status.