IXW-MA(A) Programming
IXG and IX Series Stations use SIF signaling to trigger outputs on IXW-MA(A) Multi-Purpose Adaptors. This can
be used to mirror outputs on the stations for door release or external signaling.
Adding IXW-MA(A) to a System
Navigate to Site Settings, I/O Adaptor Registration. There will be a list of up to 99 adaptors. Place a check in the
Enable column for each adaptor to be added. Click
Navigate to Network Settings, IP Address. Enter an IP address, subnet mask, and (optionally) a default gateway
for the newly added adaptors. Click
Configuring Stations for SIF Signaling
Navigate to Function Settings, SIF. For each station that will signal the IXW-MA(A), set SIF Functionality to
Enable. Under the SIF Settings column, set the Program Type to 0100, enter the IP address of the IXW-MA(A)
under IPV4, set the Destination Port to 65014, set SSL to Enabled, and Connection to Socket.
The IXW-MA(A) itself does
not need any programming
in this section.
Scroll right to the Transmission Trigger section. For each station signaling the IXW-MA(A), check off
Change Contact. Once these settings are configured, click
16 | IXG Quick Start Programming Guide