IXGW-TGW. This guide assumes that the rest of the IXG Series system has been progammed and is operational, including providing the IXGW-TGW with an IP address, assigning it to the desired units, and configuring it for mobile app use (if required). If these steps have not been completed, consult the IXG Quick Start Programming Guide here: https://www.aiphone.com/IXG-Series-QuickStartGuide...
Next, the IXGW-TGW will need to be configured to operate the installed SIM card. Navigate to Gateway Settings, Gateway SIM Settings. Fill in the following information: APN: iot0723.com.attz User Name: aiphone Password: aiphone Authentiation Type: PAP (default setting, do not change)
Telephone Entry Settings The telephone numbers will need to be registered. This can be done either through IXG Support Tool, or by calling the IXGW-TGW’s phone number directly. Some settings will need to be done in IXG Support Tool, regardless of which registration method is used. Shared Settings In the top right, there are two cells for Phone Entry Codes.
Telephone Entry Settings (continued) Registering Phone Numbers by Telephone If any settings changes were made under Telephone Entry Settings, upload settings to all stations in Connection(S), Upload Settings before performing phone registration. Provide whoever will register the phone with the Gateway Phone Number, their Unit Number, and the Default Password set for that unit (or the Password, if one has already been generated).
Status Light Codes The lights on the front of the IXGW-TGW can be used to read the status and strength of the station’s wireless connection. IXGW-TGW IXGW-TGW Legend [1] Signal strength indicator (green) [2] Wireless indicator (green) [3] Status indicator (orange/green) 8-1/4"...
Page 7
In either case, reboot the IXGW-TGW once the connection has been reestablished to end this status. For more details about the features and information above, please contact Technical Support. Aiphone Corporation | www.aiphone.com | (800) 692-0200 05/24...