Aiphone IX Series Setting Manual

Aiphone IX Series Setting Manual

Multi-purpose adaptor; software version 2.00 or later
Hide thumbs Also See for IX Series:

Advertisement

IX Series
Multi-purpose Adaptor
IXW-MA
Setting Manual (for
general users)
Software version 2.00 or later
IXW-MA
Important
• Read this "Operation Manual" prior to use to ensure safe and correct operation.
Keep this in a safe place for future reference.
• The illustrations used in this manual may differ from the actual ones.

Advertisement

Table of Contents
loading

Summary of Contents for Aiphone IX Series

  • Page 1 IX Series Multi-purpose Adaptor IXW-MA Setting Manual (for general users) Software version 2.00 or later IXW-MA Important • Read this "Operation Manual" prior to use to ensure safe and correct operation. Keep this in a safe place for future reference.
  • Page 2: Precautions

    Precautions Literature information Literature information The important information concerning correct operation and what you should observe is marked with the following symbols. This symbol means that operating the station incorrectly, or ignoring these precautions may Warning cause severe injury or death. This symbol means that operating the station incorrectly, or ignoring these precautions may Caution cause severe injury or property damage.
  • Page 3: Precautions

    Precautions Precautions Precautions Warning Negligence could result in death or serious injury. Do not disassemble or modify the station. If there is smoke, abnormal odor, abnormal This may result in fire or electrical shock. sound, or if the station is damaged, immediately disconnect the LAN cable from Keep the station away from liquid.
  • Page 4: Precautions On Operation

    • The illustrations used in this manual may differ from the actual ones. • This station is not meant to protect lives or property. Aiphone is not to be held responsible for any and all resulting serious accidents, disaster accidents, or physical damage.
  • Page 5: Table Of Contents

    Table of contents Table of contents Precautions Literature information ......................2 Literature information ......................2 Precautions ..........................3 Precautions .......................... 3 Precautions on operation ..................... 4 Before Using Part Names ..........................6 Part Names .......................... 6 Status Indicators ........................7 Status Indicators ........................
  • Page 6: Before Using Part Names

    Before Using Part Names Part Names Multi-purpose adaptor IXW-MA MAC address (The panel must be removed to access it.) Panel Reset button: This is for use by service personnel only. Do not press it. (The panel must be removed to access it.) Status indicator (orange/blue)
  • Page 7: Status Indicators

    Before Using Status Indicators Status Indicators IXW-MA Status indicator (orange/blue) : On, : Off Name Status (Pattern) Description Status Orange Booting 0.75 sec 0.75 sec indicator flashing Device error, 0.25 sec 0.25 sec startup error Communication 0.5 sec 4 sec failure Firmware version 0.25...
  • Page 8: How To Use

    How to use Other functions Sending an email An email can be sent to pre-registered email addresses using Email Event Trigger. For how to configure email settings, refer to “Email (→page 19)”. Automated email delivery email mail server Restart Example of sending email: When restarting this adaptor (Station Number: 003, Station Name: Multi-purpose Adaptor 3, Location: Rest room) △△△△@△△△△△.com Source...
  • Page 9: Settings And Adjustments Station Programming

    Settings and Adjustments Station programming Station Programming Connect to the same network as the Door Station and manage the settings from PC web browser. System requirements The programming PC must meet the following requirements to proceed. Network Ethernet (10BASE-T, 100BASE-TX) Web browser Microsoft Edge / Internet Explorer 10.0 or 11.0 / Mozilla Firefox 59 or 60 (TLS1.0, 1.1, or 1.2 enabled)
  • Page 10 Settings and Adjustments Station programming Select a language Enter the ID and password, and click [Login] • Default values – ID: user – Password: user...
  • Page 11 Settings and Adjustments Station programming Note • Do not login multiple times using multiple browsers at one time on the same PC. • The default IP address and Subnet mask values are: – IP Address: 192.168.1.160 – Subnet Mask: 255.255.255.0 •...
  • Page 12 Settings and Adjustments Station programming How to configure Click the title to configure in the setting menu • The setting window for that particular title will be shown. Configure each setting item When you are done making changes, click [Update] to update the settings •...
  • Page 13: List Of Settings

    Settings and Adjustments Station programming List of settings Reference Entry page Station Information ID and Password User ID page 14 User Password page 14 Language Language page 14 Time Time Zone Select time zone page 15 Daylight Savings Time Enable automatic daylight savings page 15 time Date and Time...
  • Page 14: Station Information

    Settings and Adjustments Station programming Station Information ID and Password Entry Description Settings Default values User ID Set the ID for logging in to the Web System 1 - 32 alphanumeric user Setting Server. characters Set the password for logging in to the Web 1 - 32 alphanumeric user User Password...
  • Page 15 Settings and Adjustments Station programming Time Important • If the power is turned off for at least 30 minutes, the time and date will revert back to the default setting. If this happens, set the time and date again. ■ Time Zone Entry Description Settings...
  • Page 16 Settings and Adjustments Station programming ■ Date and Time Clicking [Update] will not update the date and time settings on this station. Press [Apply Time to Station] to update. Entry Description Settings Default values Set date and time Set the current time for the station. This is a 2017/1/1/00:00:00 - 2037/12/ The time from 2018/1/ required setting.
  • Page 17: Network Settings

    Settings and Adjustments Station programming Network Settings ■ Enable NTP Entry Description Settings Default values Enable NTP Enable NTP server to retrieve the time. • Yes No Use Configuring NTP server is required • No Use separately if using an NTP server. Contact your system administrator.
  • Page 18: Option Input / Relay Output Settings

    Settings and Adjustments Station programming Option Input / Relay Output Settings Relay Output ■ Option Relay Control Authentication Key Entry Description Settings Default values Option Relay Control If "Option Relay Control (administrator 1 - 20 digits Authentication Key setting)" is set to "Enable," and "Speed Dials / Favorites"...
  • Page 19: Function Settings

    Settings and Adjustments Station programming Function Settings Email Configure the email function (function that sends information on station operation to the set email address). Important • If an SMTP server is not configured, email will not be sent even if email is configured. If email is not sent, contact the system administrator.
  • Page 20 Settings and Adjustments Station programming ■ Periodic Log Transmission Entry Description Settings Default values Periodic Log Select Enable / Disable for send station log • Enable Disable Transmission periodically. • Disable Periodic Log Transmit Set the time to send the periodic log. 00:00 - 23:59 00:00 Time...
  • Page 21 Settings and Adjustments Station programming ■ Send Test Email Send a test email to the address specified in “Email Addresses (→page 19)”. How to send a test email Click [Send]. The following message will be sent to the configured address. Example of sending an email message: When sending a test email from this adaptor (Station Number: 002, Station Name: Multi-purpose Adaptor 2).
  • Page 22: Maintenance

    Settings and Adjustments Station programming Maintenance Initialization Initialization puts all the settings in “List of settings (→page 13)” back to the default. How to initialize the station Click [Initialize User Settings]. Click [OK]. • Click [Cancel] to cancel the initialization process. Important •...
  • Page 23: Other

    Other Appendix Specifications Power PoE (IEEE802.3af Class 0 standard) Current Consumption Standby: 43 mA; Maximum: 135 mA Ethernet (10BASE-T, 100BASE-TX), Auto MDI/MDI-X-compatible Protocol IPv4, IPv6, TCP, UDP, SIP, HTTP, HTTPS, SMTP, SFTP, DHCP, NTP, DNS Encryption system TLS1.0, TLS1.1, TLS1.2 Operating temperature -10 - +50℃...
  • Page 24: Notice Regarding The Software

    Customers can obtain, modify, and re-distribute the source code of the software components according to the GPL/LGPL. Please see the website below for how to obtain sequence GPL/LGPL of this source code. http://www.aiphone.co.jp/data/software/source/gpl/download/ix/ * Be sure to read the following before downloading. <<Please confirm>>...
  • Page 25 OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE. (5) MIT License Copyright (c) 2018 Aiphone co.,Ltd. Released under the MIT license. Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the...
  • Page 26 (10) zlib License (C) 1995-2010 Jean-loup Gailly and Mark Adler See the following website for source code including changes for software that has been authorized under the above licenses. http://www.aiphone.co.jp/data/software/source/gpl/download/ix/ * Be sure to read the following before downloading. <<Please confirm>>...
  • Page 27 Other Notice regarding the software – Please note that we cannot answer questions regarding the content of the source code of the software components.
  • Page 28: For Proper Use Of The Station

    Other FOR PROPER USE OF THE STATION REGULATIONS This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 29: Warranty

    This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, power surge, or to use in violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory.
  • Page 30 MEMO...
  • Page 31 AIPHONE CO., LTD., NAGOYA, JAPAN Ⓑ Issue Date: Feb.2019 P0219 MQ 61331...

This manual is also suitable for:

Ixw-ma

Table of Contents