Summary of Contents for ZKTeco SpeedFace-V5L Series
Page 1
Quick Start Guide SpeedFace-V5L&H5L Series Version: 2.2 Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.
Page 2
Overview SpeedFace V5L Series Flash Near-infrared Flash Camera & Palm Collector Microphone 5" Touchscreen Card Reading Area Speaker Fingerprint Sensor Reset QR Code Scanner Thermal Infrared Temperature Thermal Imaging Temperature Detection Module Measurement Module Note: Not all products have the function with , the real product shall prevail.
Page 3
Auxiliary Input Power In RXD2 Sensor TXD2 RS232 Ethernet Exit Button +12V IWD0 RS232 Lock Wiegand IWD1 485A Wiegand Rs485 Alarm 485B Magnetic Tamper Switch SpeedFace H5L Series Flash Camera & Palm Collector Card Reading Area 5" Touchscreen Fingerprint Sensor Reset Speaker...
Magnetic Tamper Switch Terminal Block (Same as V5L) Installation Environment Please refer to the following recommendations for installation. KEEP EFFECTIVE INSTALL INDOORS AVOID DIRECT AVOID INSTALLATION DISTANCE OF ONLY SUNLIGHT NEAR 0.3 to 2m AND EXPOSURE GLASS WINDOWS AVOID USE OF ANY HEAT SOURCE NEAR THE DEVICE...
Installation Requirements The installation requirements and indications associated with the device are given below: Specification Standard value Remark Indoor, Avoid wind, Avoid The recommended operating Operating direct sunlight, temperature is 25°C (77°F) Environment 16°C to 35°C (60.8°F to 95°F) Distance The recommended distance (between face 30 to 120cm (0.98ft to 3.94ft)
Device Installation This guide uses the SpeedFace-V5L as an example for installation, wiring, introduction of functions and instructions for use. ① 1.5m ② Attach the mounting template sticker to the wall, and drill holes according to the mounting paper. Fix the back plate on the wall using wall mounting screws. Attach the device to the back plate.
Standalone Installation Alarm Smoke Detector Door Sensor Exit Button Card TCP/IP Lock Reader Power Connection 12V DC Recommended power supply 12V ± 10%, at least 3,000mA. To share the power with other devices, use a power supply with higher current ratings.
Ethernet Connection RJ 45 IP address: 192.168.1.130 Subnet mask: 255.255.255.0 Default IP address: 192.168.1.201 Subnet mask: 255.255.255.0 Click [COMM.] > [Ethernet] > [IP Address] , input the IP address and click [OK]. Note: In LAN, IP addresses of the server (PC) and the device must be in the same network segment when connecting to software.
Lock Relay Connection The system supports both Normally Opened Lock and Normally Closed Lock. The NO Lock (normally opened when powered) is connected with 'NO1' and 'COM' terminals, and the NC Lock (normally closed when powered) is connected with 'NC1' and 'COM' terminals. The power can be shared with the lock or can be used separately for the lock, as shown in the example with NC Lock below: 1) Device not sharing power with the lock 2) Device sharing power with the lock...
Page 10
Wiegand Reader/SRB Connection Wiegand card reader connects to the top 4 pins of the wiegand terminal and the last two pins are used by the Access controller, as shown in the following figure. It sends the credentials to the device via wiegand communication. +12V IWD0 IWD1...
User Registration When there is no super administrator set in the device, click on to enter the menu. Add a new user and set User Role to Super Admin, then the system will request for the administrator’s verification before entering the menu. It is recommended to register a super administrator initially for security purposes.
Page 12
Method 2: Register on ZKBioAccess IVS Software Register on the PC Please set the IP address and cloud service server address in the Comm. Menu option on the device. Click [Access] > [Access Device] > [Device] > [Search Device] to search the device on the software.
Page 13
Register on the Phone Once the ZKBioAccess IVS software is installed, the users could enroll their face via a browser application on their own mobile phone. 1. Click [Personnel] > [Parameters], input ‘’http://Server address: Port’’ in the QR Code UGL bar. The software will automatically generate a QR code. Scan the QR code or login onto ‘’http://Server address: Port/app/v1/adreg’’...
Ethernet and Cloud Server Settings Click on > [ COMM. ] > [ Ethernet ] to set the network parameters. If the TCP/IP communication of the device is successful, the icon will be displayed in the upper right corner of the standby interface. Click on >...
Page 15
Attendance Record Click on > [Attendance Search] > [Event Logs] to enter the logs query interface, input the user ID and select the time range, the corresponding event logs will be dis- played. Main Menu Attendance Search Personal Record Search Date User ID Time...
Page 16
08:50 Detection Management 08:50 ℃ Temp. Unit High body temperature Temperature measurement distance Normal temperature Temp.: 38.6 C Temp.: 36.6 C Display Thermodynamics Figure Display Body Temperature Enable mask detection Deny access without mask Allow unregistered people to access Enable capture of unregistered person Without mask Trigger external alarm Mask Detected...
Page 17
Click [Temperature Detection] > [Temperature Management] > [Real-time monitoring] to view all the events include the Abnormal Temperature, No Masks and Normal Records. Click [Temperature Management] > [Statistics Panel] to view the analysis of sta- tistical data and view the personnels with normal temperature. Real-Time Monitoring Welcome, admin 2020-05-22 11:03:07...
Page 18
Connecting to A1 Bluetooth Lock A1 Bluetooth Lock Tap [Bluetooth Settings] on the [Comm.] Settings interface to set the Bluetooth. Bind Lock Click [Bluetooth] to enable the Bluetooth function. You need to wake up the lock, the device will search through Bluetooth and display the Bluetooth lock to be bound on the [Bluetooth Settings] interface.
Page 19
Unbind Lock Tap on [Comm.] > [Bluetooth Settings], select the bound Bluetooth lock, and enter the [Details] interface. Please wake up the device first, click [Unlink Device] on the [Details] interface. The interface will pop up a "Are you sure to unlink the device?" prompt, then click [OK]. After the Bluetooth lock emits three beep sound, the interface will pop up a "Successfully unlinked.
Page 20
On the APP, click [Add Device] at Home Page. Click the icon in the upper right corner to scan the QRcode and add devices. Visitors click the on the main interface of the device to call and the phone will ring. The user can select accept or decline the call.
Page 21
LAN Video Intercom Function Settings Step 1: Install the ZKBioAccess IVS Software and ZKBio VMS Plugin Choose the "Video-VMS" module of the ZKBioAccess IVS software to install. (The Video module and the Video-VMS module cannot be installed together.) Install the ZKBio VMS Plugin. (To recognize the intercom function, the ZKBioAccess IVS software and the ZKBio VMS Plugin must be opened simultaneously.) Step 2: Configuration Parameters...
Page 22
Configure the parameters on the device Click on > [COMM.] > [Cloud Server Setting] to set the server address and server port, that is, the IP address and port number of the server after the software is installed. The icon is displayed in the upper right corner of the standby interface when the device communicates with the server successfully.
Page 23
Step 3: Adding Device on ZKBioAccess IVS Software Click [Access] > [Device] > [Device] > [Search] to add the device on the ZKBioAccess IVS software. After the device is added successfully to the access module, it automatically adds to the video module. User can click [Video] > [Video Device] > [Search] to view. (If the device is not added to the Video module, please check whether the parameter set- tings are correct.)
Page 24
Step 4: Video Preview Click [Video] > [Real-Time] > [Video Preview] to enter the preview interface of the device. Step 5: Make a Call on the Device Click on icon on the main interface of the device to get to the call window. The user can click icon to accept the call, click icon to take a snapshot, or click...
Page 25
Connect to ZKBio Talk Keep the parameter settings of ZKBioAccess IVS software unchanged. And then install the ZKBio Talk software. Click on > [System] > [Video intercom parameters] > [Intercom Server Setting] on the device, to change the server address and server port. Server Address: Enter the current server installation IP address.
SIP Settings This function needs to be used with the indoor station Vpad A2. Local Area Network Use Set the IP address on the indoor station. In LAN, the IP addresses of the indoor station and the SpeedFace-V5L must be in the same network segment. Network Accounts 1.
Page 27
Custom the Punch Status Options Configure SIP parameters for SpeedFace-V5L on the Webserver. WebServer Excel Gateway Dialing Number IP Address Subnet Mask SIP Settings 192.168.163.199 255.255.255.0 192.168.163.1 Download Configuration 192.168.163.102 255.255.255.0 192.168.163.1 192.168.163.103 255.255.255.0 192.168.163.1 192.168.163.104 255.255.255.0 192.168.163.1 WebServer WebServer SIP Settings SIP Settings Upload Configuration Data...
Page 28
SIP Server On SpeedFace-V5L, tap [SIP Server], after the device is rebooted, enter the server- related parameters For more details, please refer to the SpeedFace-V5L&H5L Series User Manual.
Page 29
Set up on Armatura Connect The Branch/Partner needs to create a customer on the ACMS first. Then add an installer and assign the installer to the customer. Once the installer has activated the account, the SpeedFace-V5L Series can be assigned.
Page 30
Search for the "Armatura Connect" App in the iOS App Store or the Google Play Store. Install and log in to the installer account. Login the Armatura Connect App. 12:00 Bind devices and set up company assignments.
Page 31
Setting the card mode, then you can swipe the card with the mobile phone close to the SpeedFace-V5L Series, or swipe the card remotely within the set range. For more details, please refer to Armatura CONNECT User Manual and Armatura ID User...
Page 32
QR Code Verification On the Server, choose [System] > [Authority Management] > [Client Register] to add a registered App client. Open the App, enter the IP address or domain name of the server, and its port number, scan the QR Code of the new App client. After the connection is successful, tap on Employee to switch to Employee Login screen.