Huawei LUNA2000-7-S1 User Manual page 118

Table of Contents

Advertisement

LUNA2000-(7, 14, 21)-S1
User Manual
Table 7-5 Impact of forced check
ESS
Worki
ng
Mode
TOU
Maxim
um
self-
consu
mptio
n
Issue 01 (2024-03-27)
Current Charge/
Discharge
Status
Charging
Discharging
The PV power is
greater than the
load power and
battery charge
power, and the
surplus PV power
is fed to the grid.
The PV power is
greater than the
load power, and
batteries are
charging.
The PV power is
less than the
load power, and
batteries are
discharging.
Copyright © Huawei Digital Power Technologies Co., Ltd.
Impact of Forced Check on
Charging
The ESS working mode is
not affected. Batteries are
charging at the maximum
power.
Batteries stop discharging
and are charging at the
maximum power.
The ESS working mode is
not affected. Batteries are
charging at the maximum
power.
Batteries are charging at the
maximum power. Power
from the grid may be
supplied to loads.
Batteries stop discharging
and are charging at the
maximum power. More
power from the grid is
supplied to loads.
7 ESS Maintenance
Impact of Forced
Check on
Discharging
Batteries are
discharging at the
current load power
(the discharged
battery energy
cannot be fed to the
grid).
1. When the battery
discharge power is
greater than the
load power, the
battery discharges
and the surplus PV
power cannot be fed
to the grid. The
inverter power is
limited, affecting the
energy yield.
2. When the battery
discharge power is
less than the load
power, the PV power
is supplied to loads
at the same time.
112