Huawei LUNA2000-7-S1 User Manual page 103

Table of Contents

Advertisement

LUNA2000-(7, 14, 21)-S1
User Manual
Alarm
Alarm Name
ID
3007
Battery
expansion
module cable
disconnected
Issue 01 (2024-03-27)
Severity
Possible Cause
Major
1. The power cable to the
battery expansion module
is disconnected.
2. The battery expansion
module is abnormal.
Copyright © Huawei Digital Power Technologies Co., Ltd.
7 ESS Maintenance
Suggestion
1. Turn off the inverter AC
output switch, inverter DC
input switch, and battery
DC switch, and wait for 5
minutes.
2. Check whether the
power cable is securely
connected to the
[Battery-1/2 battery
expansion module-1/2/3]
(whether the terminal is
loose or disconnected, or
the cable is disconnected).
For details, see the quick
installation guide. Method
for checking terminal
connections: Connect
battery expansion modules
to the power control
module one by one. If all
battery expansion modules
work properly, the bottom
terminals of one or more
battery expansion modules
are faulty. In this case,
exchange the positions of
the lowest normal battery
expansion module and the
battery expansion module
at the bottom. If none of
the battery expansion
modules works properly,
replace the power control
module. Otherwise, replace
the faulty battery
expansion module/
modules.
3. After checking that the
cables are correctly
connected, turn on the
battery DC switch, inverter
AC output switch, and
inverter DC input switch in
sequence.
4. If the alarm persists,
contact the vendor or
technical support.
97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Luna2000-14-s1Luna2000-21-s1

Table of Contents