E6A: Heating Relay Sensing Faulty; E6H: Heating Element Power Relay Faulty (Incongruence Between Sensing And Relay Status) - Electrolux EWM09312 Service Manual

Hide thumbs Also See for EWM09312:
Table of Contents

Advertisement

E6A
Checks to perform:
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
E6H: Heating element power relay faulty (incongruence between
E6H
Checks to perform:
Run the diagnostic cycle
and fill with water up to the
door level to make sure the
heating element is
completely submerged.
Measure between the wiring
connector J6-1/J6-2 and the
appliance body.
(see fig. 6)
Is the circuit open?
YES
Replace the main circuit
board and repeat the
diagnostic cycle to check for
any further alarms.
Fig. 15
Fig. 6
2012 SOE/DT-mdm FCPD-dp
Guide to diagnostics of EWM09312 electronic controls

E6A: Heating relay sensing faulty

sensing and relay status)
Detach the connector
and measure between
the heating element
NO
and the earth contact.
(see fig. 15)
Is the circuit open?
YES
Check/replace the wiring and repeat the diagnostic cycle to
General earthing
connection
Washing heating
element
!
Check that all the connectors are correctly inserted
If there are burns on the circuit board,
!
!
Check that all the connectors are correctly inserted
NO
check for any further alarms.
!
54/69
see page 67
Run phase 8 of the diagnostic
cycle, drain water from the tub.
Replace the heating element
and repeat the diagnostic cycle
to check for any further alarms.
MAIN CIRCUIT
BOARD
If there are burns on the circuit board,
see page 67
599 75 18-74 Rev.00
E6A
E6H

Advertisement