Ed2
Checks to perform:
Check if the belt of the motor
fan is correctly fitted – (fig. 21) –
Is the bel OK?
YES
Check for possible clogging of
the condenser (see fig. 24).
Is the condenser OK?
YES
Perform phase 9 of the
diagnostic cycle and
check that the motor fan
starts to run after 15 sec.
Does the motor fan
function correctly?
YES
Continues at page 99
07-2010 SOI/DT-mdm FCPD-dp Quality-fz

ED2: Drying heating element 1 faulty

Check that all the connectors are inserted correctly
Fit the belt and reset the manually reset thermostat. To reset
the thermostat push the red button (see fig. 23). Restart the
NO
Demount and clean the condenser, reset the manually reset
NO
(see fig. 23). Restart the diagnostic cycle to check for further
Replace the motor fan, reset the manually reset thermostat.
To reset the thermostat push the red button (see fig. 23).
Measure the value of the
motor fan winding (Ω)
across terminals J8-2 ÷
NO
J8-1 of the wiring
connector (see fig. 22). Is
the value correct as
described in Tab. 3?
Replace the WD board,
reset the manually reset
thermostat. To reset the
thermostat push the red
button (see fig. 23).
Restart the diagnostic
cycle to check for further
diagnostic cycle to check for further alarms.
thermostat. To reset the thermostat push the red button
Restart the diagnostic cycle to check for further alarms.
NO
YES
alarms.
98/121
alarms.
NO
Detach the connectors
and measure the
winding value (Ω)
directly across motor
fan terminals. Is the
value correct as
described in Tab. 3?
YES
Replace the wiring and
reset the manually reset
thermostat. To reset the
thermostat push the red
button (see fig. 23).
Restart the diagnostic
cycle to check for further
alarms.
If there are traces of burning on the
circuit board, refer to page
Ed2
119-120
599 70 99-00