E42: Problems Opening Door (Device With 3 Connections With Flange) - Electrolux EWM09312 Service Manual

Hide thumbs Also See for EWM09312:
Table of Contents

Advertisement

E42:
Problems opening door (device with 3 connections with flange)
E42
Checks to perform:
Fig. 9
To check the wiring, with the door
open, measure on the following
wiring connectors:
- between wire J5-2 and J5-3,
the circuit must NOT be open
(measure the resistance value of
the PTC).
- between wire J5-1 and J5-2,
the circuit must be OPEN.
Is the system ok?
Y
E
S
Check the mechanical coupling
between the door lock and the door
latch. Is the system efficient?
YES
Replace the door lock.
Is the appliance working correctly?
YES
Repeat the diagnostic cycle to
check for any further alarms
2012 SOE/DT-mdm FCPD-dp
Guide to diagnostics of EWM09312 electronic controls
Maximum time exceeded (255 seconds)
Is the door closed
correctly?
Is the door lock
traditional with
3 connections and
YES
flange as shown in
(see fig. 9A)?
NO
NO
NO
!
Check that all the connectors are correctly inserted
NO
YES
NO
Detach the connectors and
measure on the component
(see fig. 9):
- between connectors 3 and
4, the circuit must not be
open (measure the
resistance value of the
PTC).
- on the other hand,
between connectors 4 and
5, the circuit must be open
(the numbers are printed on
the component).
Is the door interlock ok?
YES
Measure the continuity
between connector J5 (main
circuit board) and the door lock
connector.
Is the wiring ok?
YES
Replace the main circuit board and repeat the diagnostic
cycle to check for any further alarms.
Replace the door latch/the door
Replace the main circuit board
and repeat the diagnostic cycle
to check for any further alarms.
!
36/69
Close the door correctly and
repeat the diagnostic cycle to
check for any further alarms.
Continued on page 38.
Traditional door lock with 3
connections and no flange
as shown in
(see fig. 28A)
Replace the
door lock and
repeat the
NO
diagnostic cycle
to check for any
further alarms.
Replace the
wiring and
repeat the
NO
diagnostic cycle
to check for any
further alarms.
If there are burns on the circuit board,
see page 67
599 75 18-74 Rev.00
E42

Advertisement

Table of Contents
loading

Table of Contents