E6A
Checks to perform:
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
E6H: Heating element power relay faulty (incongruence
E6H
Checks to perform:
Run the diagnostic cycle
and fill with water up to the
door level to make sure the
heating element is
completely submerged.
Measure between the wiring
connector J3-1/J3-2 and the
appliance body.
-(see fig.6)-
Is the circuit open?
Y
E
S
Replace the main circuit
board and repeat the
diagnostic cycle to check for
any further alarms.
Fig. 6
Fig. 19
2011 SOE/DT-mdm FCPD-dp Quality-tb
Guide to diagnostics of electronic controls EWM10931

E6A: Heating relay "sensing" faulty

between "sensing" and relay status)
Detach the connectors
and measure between
the heating element
NO
and the earth contact.
-(see fig.19)-
Is the circuit open?
Check/replace the wiring and repeat the diagnostic cycle to
Washing heating element
∞ Ω
∞ Ω
!
Check that all the connectors are correctly inserted
!
!
Check that all the connectors are correctly inserted
NO
Y
E
S
check for any further alarms.
∞ Ω
!
57/75
If there are burns on the circuit
board, see page 49
Run phase 9 of the diagnostic
cycle, drain water from the tub.
Replace the heating element
and repeat the diagnostic cycle
to check for any further alarms.
MAIN CIRCUIT
BOARD
If there are burns on the circuit
board, see page 73
599 73 77-37
E6A
E6H