Ec4: Ags Current Sensor Faulty Error; Ef1: Drain Hose Blocked/Kinked/Too High; Drain Filter Clogged/Dirty; Ef2: Excessive Detergent Dosing; Drain Hose Kinked/Blocked; Drain Filter Dirty/Clogged; Ef3: Aqua Control Device Triggered - Electrolux EWM09312 Service Manual

Hide thumbs Also See for EWM09312:
Table of Contents

Advertisement

EC4
Checks to perform:
Replace the main circuit board and run the diagnostic cycle to check for any further alarms.
EF1

EF1: Drain hose blocked/kinked/too high; drain filter clogged/dirty

Checks to perform:
This warning only appears at the end of the cycle. The appliance detected long drainage phases during
the cycle. (E.g.: More than 20 seconds when draining after rinses). Check/clean the drain filter.
EF2: Excessive detergent dosing; drain hose kinked/blocked; drain
EF2
Checks to perform:
This is an excessive detergent dosing warning. The system detected too much foam was forming during
the drain phases. Advise the Customer to use the correct quantity of detergent and to make sure the
EF3
Checks to perform:
This warns about the presence of water at the bottom of the appliance. Check for any water leaks and
Or caused by excessive overheating of the drain pump. Check for any items which may obstruct the
EF4

EF4: Water fill pressure too low and solenoid valve open

Checks to perform:
It is a warning that the water pressure is too low. If the water pressure is correct, check:
2012 SOE/DT-mdm FCPD-dp
Guide to diagnostics of EWM09312 electronic controls

EC4: AGS current sensor faulty error

Spin speed reduced to safety speed of 150 rpm
filter dirty/clogged
filter and drain circuit are clean.

EF3: Aqua Control device triggered

that the Aqua Control device float is positioned correctly.
normal operation of the rotor.
the wiring of the flowmeter and the Flowmeter.
!
Check that all the connectors are correctly inserted
If there are burns on the circuit board,
!
!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
If there are burns on the circuit board,
!
61/69
EC4
see page 67
EF1
EF2
EF3
EF4
see page 67
599 75 18-74 Rev.00

Advertisement

Table of Contents
loading

Table of Contents