Alarm
Description
Inconsistency between
E97
programme selector and cycle
configuration
Display board configuration
E9C
error
Display board sensor/touch key
E9E
faulty
Electronically controlled valve
EC1
blocked with operating
flowmeter
EC4
AGS current sensor faulty.
Drain filter clogged
EF1
(drain phase too long)
Overdosing of detergent
EF2
(too much foam during drain
phases)
Aqua control system
EF3
intervention
Water fill pressure too low,
no signal from flowmeter and
EF4
electronically controlled valve
is open
EF5
Unbalanced load
EF6
Reset
Supply frequency of appliance
EH1
outside the limits
EH2
Supply voltage too high
EH3
Supply voltage too low
2012 SOE/DT-mdm FCPD-dp
Guide to diagnostics of EWM09312 electronic controls
Possible fault
Main PCB faulty (incorrect configuration data).
Display board faulty
Display board faulty
Faulty cabling; Faulty/blocked solenoid, PCB faulty,
Main board faulty.
Drain filter clogged/dirty.
Drain hose blocked/kinked/too high.
Excessive detergent dosing; Drain hose kinked/blocked;
Drain filter clogged/dirty.
Water leaks onto base frame; Aqua control system faulty:
Drain pump winding interruption/overheating.
Tap closed, water fill pressure too low
Final spin phases skipped.
If it continues, replace the main board.
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Problem with the power supply network (incorrect/disturbed);
Main PCB faulty.
Machine status/action
Cycle blocked
----------------
----------------
Cycle stops with door locked
Drain pump continues to operate
(5 mins., then 5 mins. off. for 5 mins. etc.)
Spin speed reduced to safety speed of
Warning displayed at the end of cycle. START/RESET
Warning displayed after 5 attempts or
by the specific LED.
Appliance drains
----------------
----------------
No action to be taken
Wait for nominal
frequency conditions
Wait for nominal
voltage conditions.
Wait for nominal
voltage conditions.
17/69
Reset
RESET
START
ON/OFF
RESET
ON/OFF
RESET
RESET
150 rpm
RESET
ON/OFF RESET
RESET
START/RESET
----------------
ON/OFF
ON/OFF
ON/OFF
Page
59
59
59
60
61
61
61
61
61
62
62
62
63
63
599 75 18-74 Rev.00