E68
Checks to perform:
Run the diagnostic cycle
and fill with water up to the
door level to make sure the
heating element is
completely submerged.
Measure between the wiring
connector J6-1/J6-2 and the
appliance body.
(see fig. 6)
Is the circuit open?
YES
Replace the main circuit
board and repeat the
diagnostic cycle to check for
any further alarms.
Fig. 15
Fig. 6
2012 SOE/DT-mdm FCPD-dp
Guide to diagnostics of EWM09312 electronic controls
E68: Washing heating element leakage
Detach the connector
and measure between
the heating element
and the earth contact.
NO
(see fig. 15)
Is the circuit open?
Check/replace the wiring and repeat the diagnostic cycle to
General
earthing
connection
Washing
heating
element
∞
Ω
∞
Ω
!
Check that all the connectors are correctly inserted
NO
Y
E
S
check for any further alarms.
J14
J5
J4
GND
Fig. 4
If there are burns on the circuit board,
!
52/69
Run phase 8 of the
diagnostic cycle, drain water
from the tub. Replace the
heating element and repeat
the diagnostic cycle to
check for any further alarms.
J13
J8
J11
J10
J7
J6
∞
Ω
MAIN CIRCUIT
BOARD
see page 67
599 75 18-74 Rev.00
E68