REGULATORY COMPLIANCE (continued)
DOE Compliance Statement (PRL1500RT2UC)
This device complies with Energy Conservation Standards of the Energy Conservation Program issued by the U.S.
Department of Energy in accordance with 10 CFR Parts 429, 430 and 431, as appropriate, and the Energy Policy and
Conservation Act, as amended, under the setup as described below.
1.
Plug the UPS into a grounded AC outlet and turn on the unit via the power switch on the LCD module.
2.
Follow below steps to adjust the product settings for better energy efficiency.
(a)
Press the Menu button to enter Setup Menu and use Up/Down button to scroll to Ambient Menu. Press
Enter button to go into the selected menu.
(b)
Use the Up/Down button and Enter button to select the setting item and to complete the following setting.
i.
LED Brightness: Only power on
ii.
LCD Hibernation: After 1 minute
iii.
Cycling Display: Never
(c)
Only Power On indicator (White LED) on the LCD module will illuminate and the LCD will turn off after 1
minute of inactivity if above settings are set correctly. Pressing any button will activate the LCD.
3.
Charge the batteries for at least 80 hours while the UPS is turned on to ensure the batteries are fully charged by
leaving the UPS plugged into a grounded AC outlet under 0% load.
Note: (a) The first time you turn the UPS on, you will need to have it connected to AC power or it will not power up. (b)
If the product has been used, press Menu button to enter to Setup Menu and use Up/Down button to scroll to
Advanced Setup Menu. Press Enter button to go into the selected menu. Select the item "Back to Default", choose "Yes"
to restore the default setup of the unit and then starts from setup 1 described above.
ENERGY STAR Compliance Statement
This device complies with current ENERGY STAR Eligibility Criteria, which defines performance requirements and test
procedures for Uninterruptible Power Supplies (UPSs)
1.
Plug the UPS into a grounded AC outlet and turn on the unit via the power switch on the LCD module.
2.
Follow below steps to adjust the product settings for better energy efficiency.
(a)
Press the Menu button to enter Setup Menu and use Up/Down button to scroll to Ambient Menu. Press
Enter button to go into the selected menu.
(b)
Use the Up/Down button and Enter button to select the setting item and to complete the following setting.
i.
LED Brightness: Only power on
ii.
LCD Hibernation: After 1 minute
iii.
Cycling Display: Never
(c)
Only Power On indicator (White LED) on the LCD module will illuminate and the LCD will turn off after 1
minute of inactivity if above settings are set correctly. Pressing any button will activate the LCD.
3.
Charge the batteries for at least 80 hours while the UPS is turned on to ensure the batteries are fully charged by
leaving the UPS plugged into a grounded AC outlet under 0% load.
Note: (a) The first time you turn the UPS on, you will need to have it connected to AC power or it will not power up. (b)
If the product has been used, press Menu button to enter to Setup Menu and use Up/Down button to scroll to
Advanced Setup Menu. Press Enter button to go into the selected menu. Select the item "Back to Default", choose "Yes"
to restore the default setup of the unit and then starts from setup 1 described above.
 