LCD OPERATION GUIDE (continued)
Submenu / Config NCL
Item
NCL Switch
Delay Turn On
Delay Turn Off
Reboot Duration
Minimum Restored
Capacity
Uptime on Battery
Reserved Runtime
Off on Overload
Off on Battery
Capacity
Power Failure Delay
Off
Battery to Line Delay
On
Default
On
Delay On
Off
On
Delay Off
Reboot
Delay Reboot
4 seconds
0-600 seconds
4 seconds
0-600 seconds
12 seconds
4-300 seconds
0%
0-100%
Enable: 5-1800
seconds
Disable
Disable
Enable: 0-1800
seconds
Disable
Disable
Enable
Disable
Disable
0%
0-100%
0-7200 seconds
Never Off
Never Off
0 second
0-7200 seconds
Option
This is the main switch for NCL outlet groups.
The amount of time that the NCL outlets will wait
before actual startup. This setting only applies to
"NCL Switch."
The amount of time that the NCL outlets will wait
before actual shutdown. This setting only applies
to "NCL Switch."
The amount of time that the NCL outlets will
remain off before the UPS restarts the NCL
output. This setting only applies to "NCL Switch."
It is the criteria for UPS to turn on the off NCL
outlets as utility is restored. If battery capacity is
higher than this setting, the NCL outlets will be
turned on.
Set the maximum runtime on battery mode for
NCL outlets. The UPS will cut off NCL output after
the amount of time spent in battery mode has
reached this setting. Make sure the estimated
runtime is larger than this setting; otherwise, the
UPS will still stop supplying power when it is
running out of battery.
When the UPS is in battery mode, it will cut off
NCL output power when the remaining runtime
reaches the level.
NCL outlets will be turned off when the UPS is
overloaded in battery mode if the item is enabled.
NCL outlets will turn on automatically as utility is
restored.
In battery mode, NCL outlets will be turned off
when the battery capacity reaches the setting
value to save energy for equipment connected to
CL outlets. NCL outlets will turn on automatically
as utility is restored.
The amount of time that the NCL outlets will
provide power in battery mode if power failure
event has been triggered. After the amount of
time, the NCL outlets will be turned off. NCL
outlets will turn on automatically as utility is
restored.
The amount of time that the off NCL outlets will
wait to be turned on while switching from battery
mode to line mode.