CyberPower PR3000 User Manual

CyberPower PR3000 User Manual

Professional rack mount ups
Hide thumbs Also See for PR3000:

Advertisement

Quick Links

User's Manual
Professional Rack Mount UPS
PR3000
ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT:
www.cyberpowersystems.com

Advertisement

Table of Contents
loading

Summary of Contents for CyberPower PR3000

  • Page 1 User’s Manual Professional Rack Mount UPS PR3000 ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT: www.cyberpowersystems.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SAFETY WARNINGS……………………………………………….….………….3 BLOCK DIAGRAM……………………..………………………………………….4 INSTALLATION………………..……………………………….…………………..4 - UNPACKING………...……………………………………………………….4 - HOW TO DERTERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT…………………………………………………………………4 - TO ESTIMATE POWER REQUIREMENTS………………………………5 - HARDWARE INSTALLATION………………………………………………5 BASIC OPERTAION……………………….………………………………………8 -FRONT PANEL DESCRIPTION……………………….……………………8 -REAR PANEL DESCRIPTION…………….………………………………..9 TROUBLESHOOTING……..………………………..…………..……..…..….…12 TECHNICAL SPECIFICATION…………………………………….…………….13 DEFINITIONS FOR ILLUMINATED LED INDICATORS…………………..….14 BATTERY REPLACEMENT……..……………..…………………………..…….15 - BATTERY REPLACEMENT PROCEDURES……………………………16 LIMITED...
  • Page 3: Safety Warnings

    PR3000 Guaranteed Uninterruptible Power System SAFETY WARNINGS This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate. The AC power outlet must be installed near the ups and must be easily accessible.
  • Page 4: Block Diagram

    EQUIPMENT 1. Insure that the equipment plugged into the five battery power-supplied outlets does not exceed the UPS unit’s rated capacity (3000VA/2200W for PR3000,). If rated unit capacities are exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
  • Page 5: To Estimate Power Requirements

    PR3000 Guaranteed Uninterruptible Power System TO ESTIMATE POWER REQUIREMENTS: 1. ______Watts (W) x 2.0 = _____VA or _____Amps (A) x 120 = _____VA 2. Add the totals up for all pieces of equipment and multiply this total by 0.6 to calculate actual requirements.
  • Page 6 (b.) Connect the black wire and the red wire of the Battery Pack to the negative (-) / black terminal and the positive (+) / red terminal of the PR3000 respectively. (See Figure 1) **Note: Due to the large current, make sure to connect the positive to positive and the negative to negative.
  • Page 7 PR3000 Guaranteed Uninterruptible Power System Figure 1: Connecting PR3000 with Battery Pack...
  • Page 8: Basic Opertaion

    BASIC OPERATION FRONT PANEL DESCRIPTION Power Switch Press the power button to turn the UPS ON or OFF Test Switch The PR-UPS performs a self-test automatically when power on. If the UPS passes the test, it returns to on-line operation. If the UPS fails the self-test, please recharge the battery for 4 hours and perform another self-test.
  • Page 9 PR3000 Guaranteed Uninterruptible Power System Load Level Indicators This indicator shows a visual depiction of the UPS load. The load indicator LED will turn orange if the load is between 80 and 100%. If the load is under 20%, no indicator LED will illuminate.
  • Page 10: Rear Panel Description

    REAR PANEL DESCRIPTION Circuit Breaker Reset for Overload Protection Re-settable circuit breakers provide optimal overload protection. Battery Backup and Surge Protection Outlets Provides two battery powered, surge protected and AVR outlets for connected equipment and insures uninterrupted operation of connected equipment during a power failure. Individual Backup Power for Critical Load Provides a battery powered, surge protected and AVR outlet for the most critical connected equipment and insures...
  • Page 11 PR3000 Guaranteed Uninterruptible Power System Dual Serial Ports The PR3000 provides two serial ports to allow connection and communication between the UPS and two computers. (See Figure 2) This allows the simultaneous shutdown of two computer systems. These interfaces are also compatible with the UPS service provided by Windows 2000, Windows NT, Windows XP, Windows Server 2003 and Mac OS 10X.
  • Page 12: Troubleshooting

    Batteries are discharged. Recharge the unit for at least 4 hours Unit has been damaged by a Contact CyberPower surge or spike. tech@cyberpowersystems.com Recharge the battery by leaving the UPS The UPS does Battery is not fully charged.
  • Page 13: Technical Specification

    PR3000 Guaranteed Uninterruptible Power System TECHNICAL SPECIFICATIONS Model PR3000 Capacity (VA) 3000VA Capacity (Watts) 2200W Input Voltage Range 85 – 150Vac Frequency Range 47 – 63Hz Output On Battery Output Voltage Pure Sine Wave at 120Vac +/- 5% On Battery Output...
  • Page 14: Definitions For Illuminated Led Indicators

    Overload- Turn the UPS off and unplug at least one Long Beep piece of equipment from the UPS. Wait 5 seconds, reset the circuit breaker and restart the UPS. Surge Protection Malfunction- Power surge has damaged the unit. Please contact CyberPower.
  • Page 15: Battery Replacement

    PR3000 Guaranteed Uninterruptible Power System BATTERY REPLACEMENT Contact your dealer or call the CyberPower Technical Support in this manual for information on battery replacement. Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Servicing the battery can only be performed by trained personnel knowledgeable of batteries and their precautions.
  • Page 16: Battery Replacement Procedures

    BATTERY REPLACEMENT PROCEDURE: 1. Remove the right side 2. Remove the two retaining front panel. screws of the cable protection cover then remove the cover. 4. Remove the four 3. Disconnect the black and red cable. 5. Pull the battery pack out from the unit.
  • Page 17 PR3000 Guaranteed Uninterruptible Power System 7. Slide a new battery pack into the unit. Assemble the screws, cover, cable and front panel in the reverse sequence of above steps. 8. Recharge the unit for 4-8 hours to ensure the UPS performs expected...
  • Page 18: Limited Warranty And Connected Equipment Guarantee

    Limited Warranty and Connected Equipment Guarantee.) LIMITED WARRANTY CyberPower warrants to you, the Initial Purchaser, that the Product will be free from defects in material and workmanship for three years from the date of original purchase, subject to the terms of this Limited Warranty.
  • Page 19 CyberPower will inspect and examine the Product within ten (10) days of receipt. If the Product is not as warranted, CyberPower will repair or replace the Product and return it to you at CyberPower's expense, or, if CyberPower is unable to or decides not to repair or replace the Product (if defective) within a reasonable time, CyberPower will refund to you the full purchase price you paid for the Product (purchase receipt showing price paid is required).
  • Page 20 1. Provide reasonable proof of purchase (for example, a sales receipt) that establishes you as the Initial Customer of the Product. 2. Call CyberPower at (952) 403-9500 or (877) 297-6937 (toll free), write to CyberPower at 5555 12th Ave East, Suite 110, Shakopee, MN 55379, or e-mail CyberPower at claims@cyberpowersystems.com within ten (10) days of the date of the event for which...
  • Page 21 Connected Equipment and Request a Return Materials Authorization (RMA). 4. Pack and ship the Product to CyberPower and, if requested, the item(s) of Connected Equipment, a repair cost estimate for the damage to the Connected Equipment, and all claim forms that CyberPower provides to you.
  • Page 22 Equipment or the Product by a facility or entity not approved by CyberPower voids this Connected Equipment Guarantee. If CyberPower determines, in its sole discretion, that it is impractical to ship the damaged equipment to CyberPower, CyberPower may designate, in its sole discretion, an equipment repair facility to inspect and estimate the cost to repair such equipment.
  • Page 23 DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT OR OTHER HIGH RISK ACTIVITIES CyberPower does not sell the Products for use in high-risk activities. The Product is not designed or intended for use in hazardous environments requiring fail-safe performance,...