device, keyboard, and the front connectors. Objects on the keyboard may
damage the screen, or keyboard, or cause damage to the CCU seals.
Maintenance:
Do not use a high-pressure water jet (i.e., a pressure washer) to clean down the
Maxprobe CCU as water may get into the box, and damage may occur to the
protective seals, batteries, and printed circuit boards. Wipe down the screen and
keyboard with a clean, damp cloth. Close the box then use a low-pressure
hosepipe and a damp cloth to clean the exterior of the Maxprobe CCU if
necessary.
Note:
It is the sole responsibility of the user to keep the equipment to a good standard,
any repairs required due to negligence will invalidate the warranty and will be
chargeable. If systems are presented to a Scanprobe Techniques Limited
approved service centre in a soiled condition, a cleaning charge will be levied to
cover the additional time spent sanitising the system prior to undertaking repairs.
To increase the service life of your Maxprobe equipment we recommend the devices and
components are kept clean and serviced regularly. To achieve the greatest improvement in
longevity, pay close attention to moving parts such as rollers.
The system should be cleaned as frequently as necessary. When dirt is visible, it is
recommended to clean the system to avoid the build-up of particles, which makes the
system more difficult to clean later.
•
Always be vigilant and clean/replace parts after every inspection according to
their condition.
•
Check for loose parts like the lens holder and roller screws after every
inspection.
•
Clean camera heads with water after use and remove all debris (a soft brush
maybe required). Remove any fitted camera skids and clean between the
camera and skid.
•
Ensure the connector contacts are clean, use an electrical contact cleaner if
cleaning is required.
•
Always screw the protective caps on all connectors if the camera has been
removed.
•
Use clean water only, do not add any cleaning products.
•
If the Maxprobe keypad/screen has been used in the rain, dry any water off the
keyboard and screen with a clean cloth and leave the lid open in a warm, dry
place until all water has evaporated.
•
Keep all power leads, chargers, and electrical accessories clean and dry.
•
Thoroughly clean all parts that have had contact with the inspection area. Wipe
them over with a cloth, if necessary, after every use.
•
Roll cables up neatly after use and place in a dry area.
•
Wipe the push rod with a rag after use.
The individual system components should be kept clean and in good condition to increase
the longevity of your Maxprobe CCU and to reduce the risk to the operator while operating
the system. Maintaining the system in a clean working condition will also reduce abrasion
Maxprobe User Manual
Version 2.0
22 November 2023
39