2.3. Deploying a Basic ALX-9000 System

The AX-9000 provides a variety of communication interface to suit a range of application. Here is a
simple application for using the ALX-9000.
Step 1: Connect the positive terminal (+) of the power supply to the terminal PWR1/2 and the
negative terminal (-) of the power supply to the P.GND
Tips & Warnings
1. The input range of power supply is +10 to +30 V
2. The ALX-9000 have two power inputs that can be connected simultaneously
to the two independent power sources. If one power source fails, the other
source takes over automatically. Redundant power input help assure
non-stop operation of the ALX-9000.
Step 2: Connect the USB mouse or the USB keyboard to the USB port
Step 3: Connect the monitor to the VGA or HDMI port