INDEX 1. General Information – Intended Use, Warnings & Cautions 2. How to Use Wheel System (Retractable) Adjustable Foot Wheel System - Large Mobile Wheel Design Wheel System - Independently Braking Castors Adjusting the Height of the Couch Adjusting the backrest, footrest & tilt Extending/Retracting the Leg Rests/Foot Sections (Versa Only) Arm Loops...
1. General Information CONGRATULATIONS on the purchase of your new SEERS MEDICAL product. If these operating instructions are adhered to, the product will provide many years of safe use. If these operating instructions are not followed, your warranty could be invalid! Always keep these Instructions for Use available for reference.
Page 6
WARNINGS! Warnings identify potential hazards which if not followed correctly, could result in serious injury, or possibly death! • Ensure electric couches are not used in the presence of flammable gasses such as an anaesthetic agent. • DO NOT EXCEED the Maximum Safe Working Load of the product. •...
Page 7
How To Use Wheel System (Retractable) Lever DOWN Lever LOCKED DOWN Lever UP Wheels ENGAGED and Wheels LOCKED and Wheels RETRACTED and OFF WARNING! This product is not designed for patient transportation. Ensure wheels are retracted/locked prior to patient transfer or treatment. Disconnect the electric lead prior to re-locating the product, ensuring the lead is not trapped in the mechanism.
Adjustable Foot CAUTION! Ensure Wheels are retracted before adjusting the adjustable foot. Ensure the wheels are retracted and off. Adjust the foot by turning clockwise or anti-clockwise until the couch is stable on all legs. Secure the foot by tightening the nut until it locks against the threaded cap.
Page 10
Adjusting the Height of the Couch To adjust the height of the couch, simply press the height function button indicated by the symbol, at the top of the handset. Once selected, the graphic in the display window changes to show the Hi-Low function has been chosen.
Page 11
Adjusting the backrest, footrest & Tilt Gynae Pro – NV8483, NV8583, NV8683 To adjust the backrest, select the backrest function (B) and press the raise or lower button (E), indicated by the symbol, until desired angle is achieved. Once the button is released, the section is locked in that position, ready for use.
Page 12
Versa Pro NV0495, NV0595, NV0695 To adjust the backrest, select the backrest function (B) and press the raise or lower button (F), indicated by the symbol, until desired angle is achieved. To adjust each footrest, select the footrest function (Right = C, Left = D) and press the raise or lower button (F), indicated by the symbol, until desired angle is achieved.
Page 13
Extending/Retracting the Leg Rests/Foot Sections (Versa Only) To extend or retract the leg rest, undo the locking knob on the underside of the upholstery until the section can be moved easily. Adjust the leg rest to the desired position. Re-tighten the locking knob to secure the leg rest.
Page 14
Adjustment of Fold Down Arms (Versa Only) To raise or lower the armrest, simply swing into the up or down position. Adjusting the Angle of the Arms in the Down Position The angle in the down position can be adjusted by rotating the adjusting barrel on the underside of the arm, until the desired angle is achieved.
Page 15
l. Removable Leg Extension (Gynae Only) To use the extension, simply engage the extension into the receiving brackets and secure by tightening the locking lever on the underside. CAUTION! The Removable Leg Extension is not designed to be used as a seat. Patient weight should not be concentrated on the end of the couch.
Page 16
n. Leg Supports & Stirrups 1. To adjust the angle of the leg support, loosen locking knob on underside (A) and adjust support to desired position. 2. Re-tighten locking knob to secure. 3. To adjust height of the leg support, loosen locking knob on underside (B) and adjust support to desired height.
o. Foot Switch Operation Versa Pro – NV9212 Press the up or down button on: A. To adjust the height of the couch in the respected direction. B. To adjust the backrest of the couch in the respected direction. C. To adjust the left footrest in the respected direction. D.
3. Cleaning Instructions WARNING! Disconnect the couch from the mains power supply prior to carrying out any cleaning or decontaminating. DO NOT SATURATE PRODUCT! IF THE PRODUCT GETS SATURATED DURING CLEANING, THIS COULD ACCELERATE CORROSION, REDUCING PRODUCTS LENGTH OF SERVICE. General Cleaning To get rid of any dust or marks on the surface the Faux Leather MUST be wiped DAILY with a moist soft cotton cloth.
Page 19
Stain Removal Blot excess liquid as quickly as possible with a clean 100% cotton white absorbent cloth or sponge. If necessary use clean warm water. Clean the entire area where the spot occurred on the cushion, arm etc. Water may dissolve dirt particles and make cleaning easier.
Page 20
Frequency of routine couch cleaning will depend on exact application. 1. Ensure the couch is in a suitable area for cleaning. 2. The couch must be OFF the wheels. 3. Disconnect from mains power supply if electric model. 4. Control handsets can be wiped overusing an alcohol wipe. 5.
4. Maintenance WARNING! Disconnect the couch from the mains power supply prior to carrying out any maintenance. All electrical maintenance should be performed by a suitably qualified person. BLUE or BROWN wires must not be connected to any earth terminal. Actions to be done by clinician Daily Weekly...
Page 22
Actions to be done by qualified personnel Once a year • Carry out a full test of all electrical couch positioning functions (backrest, height, etc.) • Check operation of the backrest/footrest. Check gas struts operate smoothly and correctly throughout all ranges of movement.
Page 23
5. Warranty and Product Lifetime SEERS MEDICAL Limited standard terms and conditions apply to this device. A copy of this is available upon request. This contains full details of warranty terms and does not affect your statutory rights. For any further information on this product, regarding spares, warranty,...
6. Troubleshooting Fault Possible Cause Solution Electrical Mains cable has become Locate control box and see whether functions not disconnected, either from the power light is illuminated and working correctly the wall socket or the that the lead is connected at both control box ends.
Page 25
Mechanical faults Squeaking or An over tight pivot point Locate the noisy pivot point, then grinding noise either a bolt or pin is not slacken the securing nut by ¼ turn rotating freely. and lubricate until noise reduces. Wheels will not Couch is not on level floor Level couch by adjusting the raise or lower...
Page 26
7. Technical Data - CLINNOVA Versa Pro Index / Model NV0495 NV0595 NV0695 Configuration Elevation Electric Control Backrest Electric Footrest Gas Assisted Tilt Electric Independent Retractable Wheel Large Mobile Wheel System Braked Castors Design Wheel Design Min. Height 52cm Max. Height 100cm Length 183 to 193cm...
Page 27
Technical Data - CLINNOVA Gynae Pro Index / Model NV8483 NV8583 NV8683 Configuration Elevation Electric Control Backrest Electric Tilt Electric Independent Retractable Wheel Large Mobile Wheel System Braked Castors Design Wheel Design Min. Height 52cm Max. Height 100cm Length 148cm Head Length 95cm Mid Length...
Page 28
Technical Data - CLINNOVA Ultra Pro Index / Model NV9496 NV9596 NV9696 Configuration Elevation Electric Control Backrest Electric Footrest Electric Tilt Electric Independent Retractable Wheel Large Mobile Wheel System Braked Castors Design Wheel Design Min. Height 52cm Max. Height 100cm Length 185cm Head Length...
Page 29
Technical Data - CLINNOVA Phlebotomy Pro Index / Model NV9496P NV9596P NV9696P Configuration Elevation Control Electric Backrest Electric Footrest Electric Tilt Electric Independent Retractable Wheel Large Mobile Wheel System Braked Castors Design Wheel Design Min. Height 52cm Max. Height 100cm Length 185cm Head Length...
Electrical Technical Data Linak Ti-Motion Control Box 100 - 240V, 50/60Hz 100 - 240VAC, 50/60Hz, 2500mA Output 120W 32V, 128VA, Standby power 0.5W Duty Cycle 10% max, 2 min ON / 18 min OFF Mains Plug Fuse Rt (UK) 5.0A x 1- IP RATING IPX 6 washable IP 54...
Page 31
Symbols Double Insulated Safe working load (Class II) Alternating current (a.c.) Manufacturer Total weight of the Manufacturing date equipment including its safe working load Complies with the Caution/Warning European Regulatory affair Refer to Instructions for Use Serial number Type B applied part. Model number Waste Electrical and Do not sit on the...