Seers Medical MG2470 Service Manual

Seers Medical MG2470 Service Manual

Innovation range couches

Advertisement

Quick Links

SERVICE MANUAL
SEERS Innovation Range Couches
Model No.'s: MG2470, MG2570, MG2670, MG2475, MG2575, MG2675,
MG3470, MG3570, MG3670, MG3475, MG3575, MG3675, MG3493,
MG3693, MG3490 & MG3690
DOC No. 07-021-SM
ISSUE DRAFT A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MG2470 and is the answer not in the manual?

Questions and answers

Summary of Contents for Seers Medical MG2470

  • Page 1 SERVICE MANUAL SEERS Innovation Range Couches Model No.’s: MG2470, MG2570, MG2670, MG2475, MG2575, MG2675, MG3470, MG3570, MG3670, MG3475, MG3575, MG3675, MG3493, MG3693, MG3490 & MG3690 DOC No. 07-021-SM ISSUE DRAFT A...
  • Page 2: General Maintenance

    1. GENERAL MAINTENANCE. CONGRATULATIONS on the purchase of your SEERS MEDICAL Product. If these service instructions are adhered too, this product will provide many years of safe and reliable use. IF THESE SERVICE INSTRUCTIONS ARE NOT FOLLOWED - YOUR WARRANTY COULD BE INVALID! Always keep these Service Instructions available for reference.
  • Page 3: Cleaning Instructions

    2. CLEANING INSTRUCTIONS. WARNING! Disconnect the couch from the mains power supply prior to carrying out any cleaning or decontaminating. DO NOT SATURATE PRODUCT IF PRODUCT GETS SATURATED DURING CLEANING, THIS COULD ACCELERATE CORROSION, REDUCING PRODUCTS LENGTH OF SERVICE. General Cleaning: To get rid of any dust or marks on the surface Vinyl MUST be wiped DAILY with a moist soft cotton cloth.
  • Page 4 Chewing gum: Place ice cubes in a plastic bag and apply on the chewing gum. Wait several minutes, lift the ice bag and remove the chewing gum. DO NOT USE CHEMICALS, SADDLE SOAP, CLEANING SOLVENTS, FURNITURE POLISH, OILS, VARNISH, ABRASIVE CLEANERS OR AMMONIA IN WATER. Frequency of routine couch cleaning will depend on exact application.
  • Page 5: Maintenance

    3. MAINTENANCE WARNING! Disconnect the couch from the mains power supply prior to carrying out any Disconnect the couch from the mains power supply prior to carrying out any maintenance. All electrical maintenance should be performed by a suitably qualified person. BLUE or BROWN wires must not be connected to any earth terminal.
  • Page 6: Troubleshooting

    TROUBLESHOOTING Fault Possible Cause Solution Electrical functions not working Mains cable has become Check beneath shroud to locate disconnected, either from the wall control box and see whether the correctly power light is illuminated and that socket or the control box the lead is connected at both ends.
  • Page 7: Warranty

    © SEERS MEDICAL Limited 2014 Manufactured in the UK by SEERS MEDICAL Limited. As part of our ongoing development programme SEERS MEDICAL Limited reserves the right to modify specifications and materials of this couch without prior notice. DOC No. 07-021-UM...
  • Page 8 1 : 11 08/10/2013 E: info@seersmedical.com lorena.danescu TOLERANCES AND NOTES, REFER 06A-6500-SF TiMotion 8000N 200mm Stroke Base Actuator W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet © SEERS Medical Ltd 2012 02-9000-AI ENSURE SHARP EDGES ARE REMOVED 1 / 1 TA1-2R-200415-523220-1101A...
  • Page 9 09/10/2013 W: www.seersmedical.com 06N-0500-SF M5 Type 'T' Nyloc Nut - BZP TO BS 8888:2000 Drawing No. Edition Sheet © SEERS Medical Ltd 2012 02-9001-AI ENSURE SHARP EDGES ARE REMOVED 1 / 1 06N-0800-SF M8 Nyloc 'T' Type Nut - BZP...
  • Page 10 14/10/2013 TOLERANCES AND NOTES, REFER 06C-0042-SF Small Cover Cap W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet © SEERS Medical Ltd 2012 02-9002-AI ENSURE SHARP EDGES ARE REMOVED 1 / 1 06B-2610-SF No 6 X 1” Self Tapping Screw...
  • Page 11 Nigel Hodder 14/10/2013 E: info@seersmedical.com TOLERANCES AND NOTES, REFER 08F-9421-ZZ Meglo Hex Bar W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet © SEERS Medical Ltd 2012 02-9003-AI 1 / 1 06F-0012-SF 12mm Capped Starlock ENSURE SHARP EDGES ARE REMOVED...
  • Page 12 TiMotion Actuator Lead 1.6 Mtrs Long TOLERANCES AND NOTES, REFER W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet 02-9004-AI 06A-6540-SF TiMotion TA7 8000N Actuator 415/615 200 Stroke © SEERS Medical Ltd 2012 1 / 1 ENSURE SHARP EDGES ARE REMOVED...
  • Page 13 TOLERANCES AND NOTES, REFER 06A-6520-SF TiMotion TA7 8000N Actuator 415/615 200 Stroke W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet © SEERS Medical Ltd 2012 02-9005-AI 1 / 1 06A-6916-SF TiMotion Actuator Lead 1.6 Mtrs Long ENSURE SHARP EDGES ARE REMOVED...
  • Page 14 E: info@seersmedical.com 06C-1000-SF 10mm Body Plug - Black TOLERANCES AND NOTES, REFER W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet 02-9006-AI 06C-0555-SF Black Hole Insert 5.5mm © SEERS Medical Ltd 2012 1 / 1 ENSURE SHARP EDGES ARE REMOVED...
  • Page 15 TOLERANCES AND NOTES, REFER 06B-1265-SF M12 x 65 Hex Head Bolt 8.8 BZP W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet © SEERS Medical Ltd 2012 02-9007-AI 1 / 1 06A-6916-SF TiMotion Actuator Lead 1.6 Mtrs Long ENSURE SHARP EDGES ARE REMOVED...
  • Page 16 06A-6916-SF TiMotion Actuator Lead 1.6 Mtrs Long TOLERANCES AND NOTES, REFER W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet 02-9015-AI 06C-0815-SF M8 x 15mm Indexing Clamp © SEERS Medical Ltd 2012 1 / 1 ENSURE SHARP EDGES ARE REMOVED...
  • Page 17 E: info@seersmedical.com 06C-0815-SF M8 x 15mm Indexing Clamp TOLERANCES AND NOTES, REFER W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet 02-9016-AI 06C-0820-SF M8 x 20 KNOB © SEERS Medical Ltd 2012 1 / 1 ENSURE SHARP EDGES ARE REMOVED...
  • Page 18 TC1-3442-2211-40 230V TC1-2165-001 E: info@seersmedical.com TOLERANCES AND NOTES, REFER W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet 02-9008-AI 06N-0508-SF M4 x 8mm Screw-in Brass Insert 1 / 1 © SEERS Medical Ltd 2012 ENSURE SHARP EDGES ARE REMOVED...
  • Page 19 TC1-2165-002 120V TC1-2242-2211-40 E: info@seersmedical.com TOLERANCES AND NOTES, REFER W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet 02-9009-AI 06N-0508-SF M4 x 8mm Screw-in Brass Insert 1 / 1 © SEERS Medical Ltd 2012 ENSURE SHARP EDGES ARE REMOVED...
  • Page 20 1 : 2 15/10/2013 lorena.danescu E: info@seersmedical.com TOLERANCES AND NOTES, REFER W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet 02-9011-AI 06N-0508-SF M4 x 8mm Screw-in Brass Insert 1 / 1 © SEERS Medical Ltd 2012 ENSURE SHARP EDGES ARE REMOVED...
  • Page 21 15/10/2013 lorena.danescu 06A-6945-SF Mains Lead for TC1 Control Box- Japan E: info@seersmedical.com TOLERANCES AND NOTES, REFER W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet 02-9010-AI Plug 1 / 1 © SEERS Medical Ltd 2012 ENSURE SHARP EDGES ARE REMOVED...
  • Page 22 M8 Nyloc 'T' Type Nut - BZP E: info@seersmedical.com TOLERANCES AND NOTES, REFER W: www.seersmedical.com TO BS 8888:2000 Drawing No. Edition Sheet 02-1058-AI 08F-5007-ZZ Support Rail - Narrow Fixing 288 Ctrs 1 / 1 © SEERS Medical Ltd 2012 ENSURE SHARP EDGES ARE REMOVED...
  • Page 23 Kenton Road Debeham Suffolk IP14 6LA t: +44 (0)1728 861590 f: +44 (0)1728 861868 info@seersmedical.com w: www.seersmedical.com © SEERS MEDICAL Limited 2014 mark on this product demonstrates conformity with the Medical Device Directive 93/42/EEC. DOC No. 07-021-UM ISSUE DRAFT A...

Table of Contents