Seers Medical Sterling Changing Table Instructions For Maintenance

Seers Medical Sterling Changing Table Instructions For Maintenance

Hide thumbs Also See for Sterling Changing Table:

Advertisement

Quick Links

Instructions
for Maintenance
Model SX1047/57
Model SX2007
Model SX3008
SEERS Sterling 1, 2 & 3
Section Couches
02-07-015-SM | ISSUE 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sterling Changing Table and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Seers Medical Sterling Changing Table

  • Page 1 Instructions for Maintenance Model SX1047/57 Model SX2007 Model SX3008 SEERS Sterling 1, 2 & 3 Section Couches 02-07-015-SM | ISSUE 2...
  • Page 2 WARNING To avoid injury, always read this Instruction for Maintenance and accompanied documents before using the product. Mandatory to read the Instructions for Use...
  • Page 3 This Instructions for Maintenance document applies to the following products: Sterling Changing Table : Model No’s : SX1047, SX1057 Sterling 2 Section Couch : Model No’s : SX2007 Sterling 3 Section Couch : Model No’s : SX3008...
  • Page 4: General Maintenance

    1. General Maintenance CONGRATULATIONS on the purchase of your new SEERS MEDICAL product. If these maintenance instructions are adhered to, the products will provide many years of safe use. If these instructions are NOT followed, your warranty could be invalid! Always keep these Instructions for Maintenance available for reference.
  • Page 5: Cleaning Instructions

    2. Cleaning Instructions WARNING! Disconnect the couch from the mains power supply prior to carrying out any cleaning or decontaminating. DO NOT SATURATE PRODUCT! DURING CLEANING, THIS IF THE PRODUCT GETS SATURATED COULD ACCELERATE CORROSION, REDUCING PRODUCTS LENGTH OF SERVICE. General Cleaning To get rid of any dust or marks on the surface the Faux Leather MUST be wiped DAILY with a moist soft cotton cloth.
  • Page 6 Stain Removal Blot excess liquid as quickly as possible with a clean 100% cotton white absorbent cloth or sponge. If necessary, use clean warm water. Clean the entire area where the spot occurred on the cushion, arm etc. Water may dissolve dirt particles and make cleaning easier. Spills that are still moist are the easiest to remove.
  • Page 7 Frequency of routine couch cleaning will depend on exact application. 1. Ensure the couch is in a suitable area for cleaning. 2. The couch must be OFF the wheels. 3. Disconnect from mains power supply if electric model. 4. Control handsets can be wiped overusing an alcohol wipe. 5.
  • Page 8: Maintenance

    3. Maintenance WARNING! Disconnect the couch from the mains power supply prior to carrying out any maintenance. All electrical maintenance should be performed by a suitably qualified person. BLUE or BROWN wires must not be connected to any earth terminal. 1.
  • Page 9 ELECTRIC MODELS ONLY 9. On electric models, check the power cable and air pipes on hand and foot switch controls, looking for any cuts, abrasions or any other deterioration that may have occurred and replace if necessary. 10. Ensure that the mains power supply plug is attached securely to the motor. 11.
  • Page 10 Actions to be done by qualified personnel Once a year • Carry out a full test of all electrical couch positioning functions (backrest, height, etc.) • Check operation of the backrest/footrest. Check gas struts operate smoothly and correctly throughout all ranges of movement. The upholstered section should lock once the release lever is no longer operated.
  • Page 11: Preventative Maintenance

    4. Preventative Maintenance 1- Hinge Pin: Remove the e-clip, tap them out, clean and grease them as necessary and ensure there is no sign of fatigue and refit them. 2- Lubrication of all the pivot points: It is important to keep the pivot points and moving parts lubricated to ensure smooth movement.
  • Page 12: Troubleshooting

    5. TROUBLESHOOTING Fault Possible Cause Solution Electrical Mains cable has Check beneath shroud to locate control box functions not become disconnected, and see whether the power light is illuminated and that the lead is connected at both ends. working correctly either from the wall socket or the control Fuse blown in mains...
  • Page 13 Fault Possible Cause Solution Mechanical faults Squeaking or A tight pivot point either Locate the noisy pivot point, then slacken the grinding noise a bolt or pin securing nut by ¼ turn and lubricate until noise reduces. Wheels will not Couch is not on level Level couch by adjusting the adjustable foot (if lock...
  • Page 14 6. Warranty and Product Lifetime SEERS MEDICAL Limited standard terms and conditions apply to this device. A copy of this is available upon request. This contains full details of warranty terms and does not affect your statutory rights. For any further information on this product, regarding spares,...
  • Page 24 : +44 (0)1728 861590 f : +44 (0)1728 861868 e : info@seersmedical.com w: www.seersmedical.com © SEERS MEDICAL Limited 2024 Advena Limited. Tower Business Centre, 2 Flr. Tower Street, Swatar, BKR 4013 Malta. mark on this product demonstrates conformity with MDR.

Table of Contents