Summary of Contents for Seers Medical Therapy Series

  • Page 1 Instructions for Use Therapy Range...
  • Page 2 WARNING To avoid injury, always read this Instructions for Use and accompanied documents before using the product. Mandatory to read the Instructions for Use...
  • Page 3 This Instructions for Use document applies to the following products: Therapy Hygiene Tables ST1551A, ST1551B, ST1561A, ST1561B, ST1651A, ST1651B, ST1661A, ST1661B Therapy 2 Section Couches ST2557, ST2567, ST2558, ST2568, ST2559, ST2569 Therapy 3 Section Couches ST3557, ST3567, ST3558, ST3568, ST3559, ST3569 Therapy Deluxe Couches ST3347, ST3347S, ST3348, ST3348S, ST3349, ST3349S Therapy Deluxe Drainage...
  • Page 4 INDEX 1. General Information – Intended Use, Warnings & Cautions 2. How to Use Wheel system - Retractable Wheel Design Adjustable foot levelling Wheel system - Large Mobile Wheel Design Adjusting the height of the couch Adjusting the backrest & foot section Height Adjustment of Arms on Plus Head Models Rasing &...
  • Page 5: General Information

    1. General Information CONGRATULATIONS on the purchase of your new SEERS MEDICAL product. If these operating instructions are adhered to, the product will provide many years of safe use. If these operating instructions are not followed, your warranty could be invalid! Always keep these Instructions for Use available for reference.
  • Page 6 WARNINGS! Warnings identify potential hazards which if not followed correctly, could result in serious injury, or possibly death! • Ensure electric couches are not used in the presence of flammable gasses such as an anaesthetic agent. • DO NOT EXCEED the Maximum Safe Working Load of the product. •...
  • Page 7: How To Use

    2. How To Use Wheel System - Retractable Wheel Design Lever Down Lever Up Wheels ENGAGED and ON Wheels RETRACTED and OFF WARNING! This product is not designed for patient transportation. Ensure wheels are retracted/locked prior to patient transfer or treatment. Disconnect the electric lead prior to re-locating the product, ensuring the lead is not trapped in the mechanism.
  • Page 8: Adjustable Foot

    Adjustable Foot CAUTION! Ensure Wheels are retracted before adjusting the adjustable foot. Ensure the wheels are retracted and off. Adjust the foot by turning clockwise or anti clockwise until the couch is stable on all legs. Secure the foot by tightening the nut until it locks against the threaded cap.
  • Page 9 Adjusting the Height of the Couch Hydraulic Elevation (-DFL) To elevate the couch, push the pedal downwards with your foot. Repeat until correct height is achieved. To lower couch, raise the pedal upwards, by putting your toe underneath the lever, lifting the lever upwards until the couch reaches the desired height.
  • Page 10 Raising the Couch 1. To elevate the couch, push the UP button on the hand or foot switch. 2. Once the desired height is achieved, release the button. 3. On releasing the button, the couch is locked at the desired position. Lowering the Couch To lower couch, push the DOWN button on the hand or foot switch.
  • Page 11 Adjusting the backrest & footrest Gas Assisted Sections To raise the backrest, simply grasp the release lever towards the upholstery and adjust the backrest to the angle desired. Releasing the lever automatically locks the section at that angle. To lower, grasp the lever again, and lower the backrest to the required angle.
  • Page 12 f. Height Adjustment of Arms On Plus Head Models Only 1. To adjust the arm rest height, 2. Slide the arm rest to the desired simply grasp the arm rest pad height and release the armrest and tilt it upwards towards the back to the horizontal position.
  • Page 13 g. Raising & Lowering the Powered Mid-Section (Drainage) WARNING! Ensure Patient is secure, with not too much angle applied, so the patient is not tipped off the couch! Ensure patient entrapment will not occur when operating powered mid- section Raising the Drainage Mid-Section (Deluxe Drainage Models only) •...
  • Page 14 h. Side Supports & Rails WARNING! Children must not play with the couch at any time. Adequately supervise children in the proximity of the couch. Ensure the Side Support Rails are Fully Engaged into Socket, prior to use. To Raise the side support rail, To Lower the side support rail, simply lift and rotate 180 simply lift out of socket and...
  • Page 15 j. Upper Limb Support 1. To adjust position of Arm Support Pad, undo the locking clamp on underside of pad anticlockwise. 2. Once loosened, move pad to desired position and re-tighten locking clamp to secure. 3. If height adjustment is required, undo the locking clamp on the vertical stem.
  • Page 16 l. Locking & Un-Locking the Sliding Frame (Traction Couches Only) Sliding Frame Open (pic 1) Sliding Frame Closed WARNING! Ensure when using the Pelvic and Thoracic Harnesses, the Sliding Top Frame must be released before applying traction.
  • Page 17 m. Traction Mount (Traction Tables Only) To raise the support table platform, unscrew the height adjustment clamp positioned on the underside of the traction platform on the vertical stem. The Platform will raise to desired height, once at the desired height, re-tighten the height adjusting clamp to secure.
  • Page 18 n. Counter Traction Straps for Traction Tables (Model No. ST6068) Two anchor brackets are provided for securing the thoracic counter traction straps. The brackets are held into position by tightening the grub screws onto the box section of the table. The brackets must be fitted with the hole situated in the bar pointing outwards.
  • Page 19 o. Flexion Stool (Model No. ST6069) WARNING! The Flexion Stool is not designed as a seat and has a maximum load of 35kg. To raise the stool, unscrew the height adjustment clamp positioned on the underside on the vertical stem. The stool will raise to desired height, once at the desired height, re-tighten the height...
  • Page 20 p. Cervical Sitting Unit (Model No. St6071) Traction Tables Only Locate the Cervical Sitting Attachment into the mounting bracket located on the backrest of the couch. Secure in position with the locking lever, by rotating clockwise into the desired hole. WARNING! When not carrying out cervical traction, remove the locking lever from the couch, so as to not interfere when using the rolling traction top.
  • Page 21: Cleaning Instructions

    3. Cleaning Instructions WARNING! Disconnect the couch from the mains power supply prior to carrying out any cleaning or decontaminating. DO NOT SATURATE PRODUCT! IF THE PRODUCT GETS SATURATED DURING CLEANING, THIS COULD ACCELERATE CORROSION, REDUCING PRODUCTS LENGTH OF SERVICE. General Cleaning To get rid of any dust or marks on the surface the Faux Leather MUST be wiped DAILY with a moist soft cotton cloth.
  • Page 22 Ink, Ball point pen, Denim, hard stains Rub the stain by means of gentle circular movements with tissue dampened with 96°alcohol and water (1:1) After this rub the surface with gentle circular movement with tissue paper to dry it. Butter, oil, grease stains Wipe excess butter, oil, or grease off the surface with a clean 100% Cotton white dry cloth.
  • Page 23 If DECONTAMINATING the couch then repeat steps above using a dilute Hypochlorite & warm water mixture (mixed at 10,000ppm) instead of warm water and soap. It is crucial that any staining is treated as soon as possible but never later than 24 hours.
  • Page 24: Maintenance

    4. Maintenance WARNING! Disconnect the couch from the mains power supply prior to carrying out any maintenance. All electrical maintenance should be performed by a suitably qualified person. BLUE or BROWN wires must not be connected to any earth terminal. Actions to be done by clinician Daily Weekly...
  • Page 25 Actions to be done by qualified personnel Min Once a year • Carry out a full test of all electrical couch positioning functions (backrest, height, etc.) • Check operation of the backrest/footrest. Check gas struts operate smoothly and correctly throughout all ranges of movement.
  • Page 26 5. Warranty and Product Lifetime SEERS MEDICAL Limited standard terms and conditions apply to this device. A copy of this is available upon request. This contains full details of warranty terms and does not affect your statutory rights. For any further information on this product, regarding spares, warranty,...
  • Page 27: Troubleshooting

    6. Troubleshooting Fault Possible Cause Solution Electrical Mains cable has become Locate control box and see whether the power functions not disconnected, either from the wall light is illuminated and that the lead is working socket or the control box connected at both ends.
  • Page 28 7. Technical Data - Therapy Hygiene Tables Index ST1551 ST1561 ST1651 ST1661 Configuration Elevation Hydraulic Electric Hydraulic Electric Control Wheel System Retractable Wheels Central Locking Castors Overall Length Large A - 186cm / Medium B - 152cm Width 65cm Minimum 41cm Height Maximum...
  • Page 29 Technical Data - Therapy 2 Section Couches Index / Model ST2557 ST2567 ST2558 ST2568 ST2559 ST2569 Configuration Elevation Electric Hydraulic Electric Hydraulic Electric Hydraulic Control Overall 195cm 176cm 186cm Length 70cm 52cm 52cm Head Length 125cm 124cm 134cm Foot Length 63cm 65cm 65cm...
  • Page 30 Technical Data - Therapy 3 Section Couches Index / ST3557 ST3567 ST3558 ST3568 ST3559 ST3569 Model No. Configuration Elevation Hydraulic Electric Hydraulic Electric Hydraulic Electric Control Overall 194cm 188cm 188cm Length 60cm 52cm 52cm Head Length Mid-Section 43cm 43cm 43cm Length 91cm 93cm...
  • Page 31 Technical Data - Therapy Deluxe Couches - Single Leg Index ST3347 ST3348 ST3349 Configuration Elevation Electric Control Overall 201cm 188cm 188cm Length 65cm 52cm 52cm Head Length Mid Section 43cm 43cm 43cm Length Foot Section 93cm 93cm 93cm Length 65cm Width Minimum 46cm...
  • Page 32 Technical Data - Therapy Deluxe Couches - Split Leg Index ST3347S ST3348S ST3349S Configuration Elevation Electric Control Overall 201cm 188cm 188cm Length 65cm 52cm 52cm Head Length Mid Section 43cm 43cm 43cm Length Foot Section 93cm 93cm 93cm Length 65cm Width Minimum 46cm...
  • Page 33 Technical Data - Therapy Deluxe Drainage Couches – Single Leg Index ST3547 ST3548 ST3549 Configuration Elevation Electric Control Overall 201cm 188cm 188cm Length 65cm 52cm 52cm Head Length Mid Section 43cm 43cm 43cm Length Foot Section 93cm 93cm 93cm Length 65cm Width Minimum...
  • Page 34 Technical Data - Therapy Deluxe Drainage Couches – Split Leg Index ST3547S ST3548S ST3549S Configuration Elevation Electric Control Overall 201cm 188cm 188cm Length 65cm 52cm 52cm Head Length Mid Section 43cm 43cm 43cm Length Foot Section 93cm 93cm 93cm Length 65cm Width Minimum...
  • Page 35 Technical Data – Therapy Two Section Tilt Table Index ST7647 ST7647DL ST7649 ST7649DL Configuration Elevation Electric Control Overall 196cm Length 71cm Head Length Foot Section 125cm Length 70cm Width Minimum 47cm Height Maximum 101cm Height Safe Working Load & Lifting 225KG (496 lbs) Capacity...
  • Page 36 Technical Data - Therapy Drop End Couches Index ST3556 ST3566 Configuration Elevation Control Hydraulic Electric Overall Length 191cm Head Length 39cm Mid-Section Length 52cm Foot Section Length 95cm Width 70cm Minimum Height 48cm Maximum Height 101cm Safe Working Load & 240Kg (528lbs) Lifting Capacity...
  • Page 37 Technical Data - Therapy Bobath Couches Index ST4552 ST4562 ST4542 ST4552W ST4562W ST4542W Configuration Hydraulic Electric Electric Hydraulic Electric Electric Elevation with gas with gas with with gas with gas with Control assisted assisted electric assisted assisted electric backrest backrest backrest backrest backrest...
  • Page 38 Technical Data - Therapy Deluxe Bobath Couches Index ST4642 ST4642W Configuration Electric with electric backrest Elevation Control 200cm Overall Length 65cm Head Length 135cm Foot Section Length 105cm 125cm Width 46cm Minimum Height 100cm Maximum Height Safe Working Load 325Kg &...
  • Page 39 Technical Data - Therapy Mat Tables Index Configuration Elevation Control Overall 195cm 198cm 200cm Length Width 105cm 125cm 150cm Minimum 46cm Height Maximum 100cm Height Safe Working Load & 250Kg (550lbs) Lifting Capacity...
  • Page 40 Technical Data - Therapy Traction Table Index ST6557 ST6567 Configuration Elevation Control Hydraulic Electric Overall Length 188cm Head Length 65cm Mid-Section Length 40cm (2x 20cm Sections) Foot Section Length 83cm Width 70cm Minimum Height 50cm Maximum Height 101cm Safe Working Load & 240Kg (528lbs) Lifting Capacity...
  • Page 41: Environmental Protection

    Electrical Technical Data Linak Ti-Motion Control Box 100 - 240V, 50/60Hz 100 - 240VAC, 50/60Hz, 2500mA Output 120W 32V, 128VA, Standby power 0.5W Duty Cycle 10% max, 2 min ON / 18 min OFF Mains Plug Fuse Rt 5.0A x 1- (UK) IP RATING IPX 6 washable...
  • Page 42 Symbols Safe working load Double Insulated (Class II) Alternating current (a.c.) Manufacturer Total weight of the Manufacturing date equipment including its safe working load Complies with the European Caution/Warning Regulatory affair Refer to instructions For Use Serial number Type B applied part. Model number Waste Electrical and Electronic Equipment...
  • Page 43 UNITED KINGDOM t: +44 (0)1728 861590 f: +44 (0)1728 861868 e: info@seersmedical.com w: www.seersmedical.com © SEERS MEDICAL Limited 2023 Advena Limited. Tower Business Centre, 2 Flr. Tower Street, Swatar, BKR 4013 Malta. mark on this product demonstrates conformity with MDR...