17. Wiring and sensor information

IO113 SM 113 information
IO113 pump configuration (DIP switches 1 and 2)
For further information see IO113 manual.
IO113
pump
Sensors
variant
configu-
ration
Standard: leakage
switch, moisture
"PA"
switch, Klixon/PTC in
each winding.
Sensor Set 1: leak-
age switch, moisture
switch, Klixon/PTC in
"PB"
each winding, Pt1000
in the stator.
Sensor Set 2: leak-
age switch, moisture
switch, Klixon/PTC in
each winding, vibra-
"PC"
tion sensor (PVS3),
Pt1000 in the stator,
lower and upper bear-
ing.
The SE/SL 9-30 kW / 12-42 Hp range does not have a Water-In-Air (WIA) or a Water-In-Oil (WIO) sensor. As such, position of DIP
switches 11 and 12 must be ON (both in the upper position).
When the Sensor Module (SM113) is used, ensure that the IO113 with communication functionality (98711370) is also used.
As this pump range does not have a WIA or WIO sensor, the SM113 must be fitted with a 2.7 kΩ resistor (see wiring diagrams) to avoid
false sensor alarms in the IO113.
Testing sensor circuits
Klixon Circuit: The pass criteria for the Klixon circuit is that the circuit is connected.
PTC Circuit: The pass criteria for the PTC circuit is between 100 ohms and 500 ohms.
Moisture/Leakage Switch Circuit: The pass criteria for the moisture/leakage switch circuit is that the circuit is connected.
64
DIP
switch
Diagram
setting
ON
1 2
PA - IO 113 without WIO/WIA sensor
A: Moisture switch
B: Thermal switches
IO 113
P1 P2
ON
A
1 2
PB - With SM 113. Thermal switches, moisture switch, WIO/WIA sensor, Pt100/Pt1000 sen-
sors
A: Moisture switch
B: Thermal switches
ON
1 2
A: Moisture switch
B: Thermal switches
C: Vibration sensor
P1 P2 P3 P4 P5
A
B
SM 113
1 2 3 4 5 6 7 8 9 1011 121314
P3 P4
P5
B
1 2 3 4 5 6 7 8 9 10 11121314
P1 P2 P3 P4 P5
A
C
B