Page 1
GRUNDFOS INSTRUCTIONS SE, SL 9-30 kW Service instructions Installation and operating instructions in English and other languages for 50/60 Hz Service animation video, YouTube http://net.grundfos.com/qr/i/98142266...
Consequence of ignoring the warning. Tightening torques and lubricants - Action to avoid the hazard. Overhaul Servicing the product Servicing Grundfos pumps with explosion-proof motors Observe these instructions for explosion-proof General information products. Checking the motor liquid Inspecting the shaft seal...
2. Safety 4. Storing and handling the pump Installation of pumps in pits must be carried out by 4.1 Handling the pump specially trained persons. The SE, SL 9-30 kW pump weighs between 290 and 690 kg Work in or near pits must be carried out according to without accessories.
Page 4
4.1.2 Installation types S, C and D 4.1.3 Installation type H Installation type H can be lifted by a hole in the flange and the front lifting point. See fig. 2. Always handle the pump by means of the correct lifting points.
4.1.4 Raising the pump to upright position 4.2 Storing the pump 1. Fasten the lifting equipment as shown in the figure below. For further information, see the installation and operating instructions for SE, SL 9-30 kW. The installation and operating instructions are accessible via the QR code andthe link on the front page of this document.
6. Service tools Standard tools Special tools Pos. Designation Description Part number Pos. Designation Description Part number Molex plug removal Circlip range SV2117 Locking-ring pliers 70147723 tool 122-400 mm Refractometer 98676968 Shaft seal 98565931 protection tool Service tool, cable 98761439 entry 7.
Position numbers of parts (numbers in brackets) refer complete overhaul of the pump is usually required. to section Drawings. Position numbers of tools This work must be carried out by Grundfos or an authorised (letters in brackets) refer to section 6. Service tools.
9.3 Checking the motor liquid 9.5 Changing the motor liquid You can check the ingress level of the media in the motor liquid. When the pump is new or after replacement of the shaft seal, check the motor liquid level and water content after one week of When using a refractometer (C), the refractive index will show the operation.
Page 9
Filling with motor liquid, vertical installation Filling with motor liquid, vertical installation: 1. Place the pump vertically. 1. Remove plug A and B on both sides. This makes it possible to get the trapped air out while filling. See fig. 10. 2.
9.6 Inspecting and adjusting the impeller clearance 9.7 Dismantling the pump Before dismantling the pump DANGER • Switch off the power supply. Electric shock • Close the isolating valves, if fitted, to avoid draining the piping Death or serious personal injury system.
Page 11
Dismantling the cable entry 9.7.4 Removing the upper bearing bracket 1. Place the service tool for cable entry (E) in a vice. 1. Remove the screws (183). 2. Mount the cable entry (168) in the service tool for cable entry 2.
9.7.8 Removing the impeller 9.7.13 Removing the upper seal housing (only SL) 1. Remove the outer screws (26). 1. Remove the screws (182b). 2. Lift the pump including the impeller out of the pump housing 2. Remove the upper seal housing (58). Use a soft hammer very (50).
Page 13
9.8.1 Fitting the bearings 9.8.7 Fitting the shaft seal 1. Heat the new upper ball bearing (154) to 120 °C, and fit it on 1. Make sure the O-rings are fitted on the shaft seal housing. If the rotor (172). the seal is to be fitted on an SE pump, remember the O-ring (106).
Page 14
9.8.9 Fitting the lower seal housing 9.8.15 Fitting the cable 1. Mount the shaft seal protection tool (D), if not fitted already. Assembling the cable entry 2. Fit the lower seal housing (77) on the upper seal housing (58). 1. Place the service tool for cable entry (E) in a vice 3.
Fitting the cable 10. Electrical connection 10. Fit the cable entry on the motor cover, and fit the screws 10.1 Motor protection (181a). 11. Tighten the screws to 70 ± 4 Nm. Galvanic separation Double-insulated sensors for all measurements of high voltages ensure the electrical safety.
Page 16
10.1.2 Thermal switches Installation of the leakage switch During the installation of the leakage switch (521) on Ex pumps The thermal protection against overheating is made with additional safety precautions must be taken. thermistors and with PTC as optional. The three thermal switches that are hard wired from pump to IO 113 unit will open if the stator The reason for this is to avoid the safety distance between the windings become too hot.
Page 17
The PVS 3 sensor is intended for use in medium- and large-size IO 113 provides the interface between the pump equipped with Grundfos wastewater products. sensors and the pump controller(s). The most important sensor status information is indicated on the front panel.
14. After one week of operation or after replacement of the shaft 11. Startup seal, check the condition of the motor liquid in the seal housing. Do not start the pump if the liquid start level is lower For pumps without sensor, this is done by taking a sample of than the stop level or if the atmosphere in the pit is the liquid.
SE 2- and Media ingress Refractive SL 6-pole SE 6-pole RM5418 RM0350 4-pole 4-pole in % index 5.4 litres 14.1 litres Grundfos HTF Demineralised 4.5 litres 12.8 litres transfer fluid water Amount of Amount of Amount of Amount of Percentage Percentage Percentage...
16. Components and material specification Pos. Component Material The position numbers in the table below refer to the sectional 182b Hexagon head screw Stainless steel drawings on the following pages. 182c Washer Stainless steel Pos. Component Material 182d O-ring Rubber Rivet Stainless steel Hexagon socket head cap screw...
Page 43
BOMBAS GRUNDFOS DO BRASIL Turkey Siu Wai Industrial Centre GRUNDFOS Pumper A/S Av. Humberto de Alencar Castelo Branco, GRUNDFOS POMPA San. ve Tic. Ltd. Sti. 29-33 Wing Hong Street & Strømsveien 344 Gebze Organize Sanayi Bölgesi CEP 09850 - 300...