11.6 Sensor wire connection, EMC cable with standard
sensor set
With the EMC version, the sensor wires are not cable-tied to the
cable bracket, but a P-clamp (CL1) is used to earth the cable shield.
Place the P-clamp onto the shield of the signal wires, ensure that it
is positioned 5 ± 2 mm (0.196 ± 0.078 in) from the end of the shield.
Mount the clamp on the bracket. Ensure that a suitable anti-seize
grease is used on the screw. The required torque is 4 ± 0.6 Nm (3 ±
0.4 lb-ft).
CL1
11.7 Sensor wire connection, single cable with sensor
set 1
Sensor set 1 is different from the standard sensor set as it has a
Pt1000 sensor mounted on the stator.
1. To complete the wiring of a single cable with sensor set 1, first
complete all the wiring steps of the standard sensor set. Ensure
that the wiring for the Pt1000 is kept in front of the cable
bracket.
2. The wiring of the Pt1000 sensor is secured to the cable bracket
by a clamp.
3. Place the cable shield below the camp.
4. Secure the clamp. The required torque is 1 ± 0.15 Nm (0.7 ± 0.1
lb-ft). Use a suitable anti-seize grease on the screw thread.
34
5. Place the Pt1000 connector pins into the male connector in
accordance with the relevant wiring diagram. Check the
connection with the male connector by pulling the wires
backwards.
Related information
17. Wiring and sensor information
11.8 Sensor wire connection, single cable with sensor
set 2
The wiring for sensor set 2 differs from the standard and sensor set
1. In addition, the SM 113 module is needed to be mounted in the
motor top.
1. Complete all the steps as prescribed in the section above
section, however:
• Do not connect the Pt1000 sensor wires into the connector.
• Do not mount the Pt1000 wires on the cable bracket.