Technical Data
Input Characteristics
Model No.
Mains voltage
Stand-by power
Load ratings:
800VA (Capacitive) 1000W (Resistive)
Max withstandable
in-rush current
Warming-up
Safety and EMC
EMC standard (EMC)
Safety standard (LVD)
Radio Equipment (RED)
Certi cation
Mechanical Structures and Installations
For more details, please refer to user manual.
A. Ceiling mount
LED indicator
Daylight sensor
PIR
Sensor module
Installation rack
Subject to change without notice.
HIM30
220-240VAC 50/60Hz
<1W
120A@160 s
30s
EN55015, EN61000
EN60669, AS/NZS60669
EN300440, EN301489-1,
EN62479
Semko, CB, CE , EMC, RED
Infrared receiver
Rotary switch for programing
Cable entry
TM
RED
Sensor Data
Model No.
Sensor principle
High Frequency (microwave), PIR
Operation frequency
Transmission power
Sensor mode
4 modes: PIR, HF, PIR+HF, PIR/HF
Detection range
Detection angle
Environment
Operation temperature
IP rating
4.1
66.6
81.5
Edition: 10 Aug. 2023
IP65
HIM30
5.8GHz +/- 75MHz (HF)
<0.2mW (HF)
Max. ( O x H) 10m x 12m
360
O
Ta: -20
O
C ~ +50
O
C
IP65
Ver. Draft
Page 1/7

Advertisement

loading
Need help?

Need help?

Do you have a question about the DUAL sense HIM30 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hytronik DUAL sense HIM30

  • Page 1 IP65 High Bay Dual Sense Sensor HIM30 IP65 HF and PIR, On/off Control with Remote Control Technical Data Sensor Data Input Characteristics Model No. Model No. HIM30 HIM30 Sensor principle High Frequency (microwave), PIR Mains voltage 220-240VAC 50/60Hz Stand-by power Operation frequency <1W 5.8GHz +/- 75MHz (HF)
  • Page 2 B. Screw to the Luminaire by conduit Infrared receiver LED indicator Rotary switch for programing Daylight sensor 59.6 Sensor module 66.6 89.9 Cable entry C. Attach to the shade by clamp Infrared receiver LED indicator Rotary switch for programing Daylight sensor Angle adjustment Luminaire clamp Sensor module...
  • Page 3: Functions And Features

    4 optional detection modes via remote control: * HF: Microwave only * PIR: PIR mode only * HF+PIR: both PIR and microwave mode, to decrease the detection capability and detection area. Only when both detections are activated, the motion is considered valid. This is to prevent the sensor from false trigger by heat source, air conditioner, ventilation fans, water pipe and elevators etc...
  • Page 4 Rotary Switch Preset A rotary switch is built inside the sensor for scene Detection Daylight Channel Hold-time selection / fast programming. Total 16 channels range sensor are available: 100% Disable 100% 1min 2Lux 100% 5min 10Lux 100% 5min 30Lux 100% 5min 10Lux 100%...
  • Page 5 Settings (Remote Control HRC-11) Press button “ON/OFF” to select permanent ON or permanent OFF mode. * Press button “AUTO”/ “RESET” to exit this mode. Press button “RESET”, perform DIP Switch/Rotary Switch settings. *The default settings are: Detection range 100%; Hold-time 5min; Daylight threshold disable;...
  • Page 6 Sensitivity & More functions 100% 75% In AUTO /SEMI-AUTO modes, press buttons in zone “Detection range” to set detection range at 100%/75%/50%/10%. 50% 10% Note: only work for HF sensitivity Tri-level This key is not appliable on this product. Harvest This key is not appliable on this product.
  • Page 7 Additional Information / Documents 1. Regarding precautions for microwave sensor installation and operation, please kindly refer to www.hytronik.com/download ->knowledge ->Microwave Sensors - Precautions for Product Installation and Operation 2. Regarding precautions for PIR sensor installation and operation, please kindly refer to www.hytronik.com/download ->knowledge ->PIR Sensors - Precautions for Product Installation and Operation...