INSTALLATION
SPECIFICATION
15.3 Removing the flanged immersion heater
15.4 Removing the protective anode
15.5 Fitting the protective anode
» To include the steel cylinder in the earthing mass, follow the
order of installation of the fixing elements of the protective
anode, see chapter "Removing the protective anode".
15.6 Descaling
» Remove the flanged immersion heater.
» Carefully tap the immersion heater element to remove larger
limescale deposits and immerse the heating element up to
the flange plate in descaling agent. Never treat the cylinder
surface or the protective anode with descaling agents.
15.7 Checking the protective anode
» Check the protective anode for the first time 2 years after
installation. For this, remove the flanged immersion heater;
see chapter "Removing the flanged immersion heater and
protective anode". Replace worn protective anodes.
» Afterwards determine the time intervals at which further
checks should be carried out.
15.8 Replace power cable
» The power cable must be replaced by a qualified electrician
with the original spare part (part no. 286211).
» Never remove the plastic thread holding the profile plate.
15.9 Temperature controller/limiter sensor
When replacing or removing the temperature controller/limiter,
reinsert the sensors into the protective pipe in accordance with
the following diagrams.
200
270
8
|PSH MINI ID
16. Specification
16.1 Dimensions and connections
100
3
200
316
1
1 Hot water connection (red)
2 Cold water connection (blue)
3 Mounting bracket
16.2 Wiring diagram
1/N/PE ~ 220 V / 230 V
1 Protective anode
2 Resistance 560 Ω
70
296
2
2
1
L N
L N PE
WWW.STIEBEL-ELTRON.COM