INSTALLATION
OPERATION
4.
Operation
4.1
Temperature selector
You can select whichever temperature you require at the
temperature selector.
The ON/OFF indicator illuminates while the water is being heated.
1
2
1 Temperature selector
"E" approx. 40 °C
"e" approx. 60 °C
Fully turned to the right approx. 82 °C
2 Indicator
4.2
Frost protection
(cold). In this position, the water heater is protected against frost.
The tap and the water line are unprotected.
4.3
Economy setting
This appliance is equipped with two economy settings, i.e. "e"
and "E". With these settings, minor scaling inside the appliance
should be expected.
4.4
Heat-up time / Outlet volume
See chapter "Specification / Data table".
5.
Cleaning, care and maintenance
» Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
» Check the taps regularly. You can remove limescale deposits
at the tap outlets using commercially available descaling
agents.
» Have the electrical safety of the appliance and the function of
the safety valve regularly checked by a heating contractor.
» Have the protective anode checked by a heating contractor
after the first two years. The heating contractor will then
determine the intervals at which it must be checked
thereafter.
4
|PSH MINI ID
6.
What to do if ...
6.1
... the appliance develops faults
Fault
Cause
The appliance fails to
The temperature selector
deliver hot water.
is set to "OFF".
There is no power.
Water can only be drawn
The perlator in the tap is
at a reduced rate.
scaled up.
Strong boiling noises
The appliance is scaled
inside the appliance.
up.
Water drips from the
The safety valve is scaled
safety valve after heating
up or dirty.
has stopped.
Where a contractor is required, they can remedy the fault more
quickly and effectively if you provide the following details from
the appliance type plate:
. . . . . .
NO:
. . . . . .
Typ:
Remedy
Switch the appliance
on by turning the
temperature selector.
Check the fuse/MCB
in your fuse box/
distribution panel.
Descale or replace the
perlator.
Have a contractor
descale the appliance;
contact customer service.
Switch off the appliance
and depressurise it, by
isolating the appliance
from the power supply
and by shutting off the
water supply. Have a
contractor check the
safety valve; contact
customer service.
WWW.STIEBEL-ELTRON.COM