INSTALLATION
TROUBLESHOOTING
14. Troubleshooting
Fault
Cause
The appliance fails to
There is no power.
deliver hot water.
The high limit safety cut-
out (STB) has responded.
Water can only be drawn
The perlator in the tap is
at a reduced rate.
scaled up.
Strong boiling noises
The appliance is
inside the appliance.
scaled up.
Reset the high limit safety cut-out
WWW.STIEBEL-ELTRON.COM
15. Maintenance
Remedy
Check the fuse/MCB
in your fuse box/
distribution panel.
» Remove the appliance for maintenance work.
Remove the cause for
this fault and replace
» For the torque of the flange screws, see chapter
the temperature
"Specification / Data table".
controller. Reset the high
limit safety cut-out by
15.1 Draining the appliance
pressing its reset button.
Drain the appliance via the connector.
Descale or replace
the perlator.
15.2 Opening the appliance
Descale the appliance.
» Pull off the rotary selector.
» Remove the screws underneath the rotary selector.
» Open the appliance cap by lowering the bolt screws inwards
and pivot the cap upwards, then remove it.
Danger of electrocution!
!
Before any work on the appliance, disconnect all poles
from the power supply.
PSH MINI ID |
7