D. Insert a screwdriver into the slot on the top of the terminator to hold it in place and torque
the nut to 7 N m.
E. Hold the terminator body stationary with the screwdriver and turn only the hex nut to
prevent the conductors from twisting out of the separator.
NOTE: Turn only the hex nut to prevent conductors from twisting out of the separator.
F. Attach the terminated cable end to the PV racking with a
cable clip or tie wrap so that the cable and terminator do not
touch the roof.
WARNING: The terminator cannot be re-used. If you
unscrew the nut, you must discard the terminator.
Step 8: Complete the installation of the junction box
A. Connect the IQ Cable to the junction box.
B. Refer to the
Sample wiring diagram
following table.
Step 9: Connect the PV modules
WARNING: Electrical shock hazard. The DC conductors of this photovoltaic system are
ungrounded and may be energized.
20
Enphase IQ8, IQ8+, IQ8M, IQ8A, and IQ8H Microinverters
for more information. Wire colors are listed in the
Wire colors
L1-black
© 2024 Enphase Energy Inc. All rights reserved.
Internal view
L2-red
January 2024
IOM-00068-1.0