EXCELL PRECISION CO., LTD.

12-1-22. Write Power-on E813 Notify Mode

This 4C(Hex) sub-command set can be written only when Calibration Mode is enabled.
Write UUID E812 handle (Hex) with the following command(s):
Calibration
Length
Sub-Command
Command
(Hex)
(Hex)
(Hex)
99
02
4C
Read UUID E812 handle, which will return 99 02 7F .... (please refer to 12-1-39 Return Read & Write
Status).
This command is for setting E813 Notify output format(s), and this command sets permanent E813
Notify output format(s). The difference between such format(s) and format(s) of 12-1-1. Temporarily
Switch E813 Notify Output Formats is that, after power-off (or Bluetooth reconnection after Bluetooth)
and subsequent power-on action, E813 Notify settings will be based on permanent E813 Notify output
formats, not the temporarily switched E813 Notify output format(s).
Execution conditions for these
commands

12-1-23. Read Power-on E813 Notify Mode

Write UUID E812 handle (Hex) with the following command(s):
Calibration Command (Hex)
99
After the above 'Read' command set is successfully written to the UUID E812 handle, there will be
return values (Hex data) after reading the UUID E812 handle, such as the following:
99 02 0C NN (for descriptions regarding the NN return value(s), please refer to 12-1-22. Write Power-on
E813 Notify Mode).
TM
1-byte
'Write' Description
Type A
Data
(Hex)
NN: (As follows)
0x00:AD Mode 1, power-on Notify AD raw value (set E812
Notify as the 85 format)
0x01:AD Mode 2, power-on Notify AD value after filtering
(set E812 Notify as the 85 format)
0x02:AD Mode 3, power-on Notify AD filtering and value
NN
after linear correction (set E812 Notify as the 85 format)
0x04: Weight Mode 1, power-on Notify weight, traditional
Excell RS232 Format ,"ST,NT,30.000Kg"
0x05: Weight Mode 2 (enable Notify weight; please refer to
the 0x84 command)
0x06: Weight Mode 3, power-on Notify weight, FOR APP,
"ST,N ,30.000Kg"
Calibration Mode
Executable
Length (Hex)
01
48
Normal Mode
Executable
Sub-Command (Hex)
0C